7. Troubles
●
Code :
S1-1313
●
Error message :
The clock became in
●
Symptom / Cause :
Saved time is invalid
●
Troubleshooting method :
1. Set up the time and reboot the MFP. Is the setting t
Yes : Status is normal.
2. Check if the battery is normal.
A. Remove the rear cover.
B. Check if the power of battery on Video board is 3
C. If the battery is dead, replace it.
3. If the problem persists, replace the Video board.
●
Replacement part
- 4301-001042 : BATTERY-LI
- JC92-02150A : PBA-MAIN (CLX-9350ND)
JC92 02235A PBA MAIN (CLX 9250ND)
- JC92-02235A : PBA-MAIN (CLX-9250ND)
Service Manual
CLX-9250/9350 series
7-9
shooting
:
nitial time. Set a time again.
ime stored?
3.3V.
SAMSUNG ELECTRONICS
94