※ In case you want more information about the controllers and accessories, please refer to the Controller and
Accessory TDB on pvi.Samsung.com site or Global Partner Portal site.
11. Installation
2
Use a standard 65 mm hole saw to drill one hole at
the selected location, at a 15° downward angle so
that the drain hose will drain properly.
Drain hose
Wall
Indoor unit
3
Based on the hole location, determine where the
piping bundle (drain hose, refrigerant pipes, and
cables) will exit the unit.
Left
Right
bottom
Rear right or left
<Front view>
<Side view>
NOTE
•
The left, right, or bottom exit will only be used if the
hole is not positioned behind the unit.
Connecting the power and communication cables
WARNING
•
Do not modify the power cable in any way. Doing
so may cause electric shock or fire due to poor
connection, poor insulation, or current limit override.
Make sure to comply with the technical standards of
electrical installations and the wiring regulations in
the local area.
•
This appliance must be properly grounded. Do not
ground the appliance to a gas pipe, plastic water
pipe, or telephone line. Failure to comply may result
in electric shock, fire, and explosion.
1
Connect each wire to its corresponding terminal
number.
Control box
Before
connecting
Correct
Upside
down
Damaged
Non-
circular
After
connecting
Correct
(Front view)
Correct
(Side view)
Upside
down
Non-fitted
<Circular terminal>
Indoor Unit Installation
Model
**09*******
**12*******
Power cable
(Outdoor unit)
3G X 2.5 mm²,
H07RN-F
Outdoor-to-indoor
power cable
3G X 1.0 mm²,
H07RN-F
Communication
cable
2 X 0.75 mm²,
H05RN-F
Type GL