ELECTRICAL WORK
INSTALLATION METHOD
Connecting the Pipe
◆
The piping of this unit can be connected to the right, left, and rear side.
When you hit the area for piping connection slightly with a hammer, a hole is made.
◆
After connecting the piping and drain hose, insert the rubber cap as shown in the figure.
Holes for piping
connection (2 points)
❈
The shape of hole may vary with the models.
Cover hole
When using ELB (Earth Leakage Circuit Breaker)
1. Remove the cover of electric box on side panel of the outdoor unit.
2. Disconnect the connector A(R-L connection) from the outdoor unit.
3. Connect the electric input wires (R,S,T) to each terminal (R,S,T) and input wires (N,L) to each terminal (N,L)
of the electric box on the outdoor unit respectively. (Input wires are purchased by the user separately.)
4. Connect the electric wires to each terminal on the indoor and outdoor unit respectively.
OUTDOOR SIDE
Power terminals on the outdoor unit
Break Connector
Blue
Brown
Blue
Brown
Electric input wires
Indoor / outdoor unit
connecting wire
Wire of sensor
A