AM280AXVDGH1EU
AM300AXVDGH1EU
AM320AXVDGH1EU
AM120AXVDGH/EU
AM120AXVDGH/EU
AM160AXVDGH/EU
AM160AXVDGH/EU
AM180AXVDGH/EU
AM160AXVDGH/EU
-
-
-
-
-
-
Ø, #, V, Hz
3, 4, 380-415, 50
3, 4, 380-415, 50
3, 4, 380-415, 50
-
HEAT PUMP
HEAT PUMP
HEAT PUMP
HP
28
30
32
Cooling(Rated)
kW
78.6
84.0
90.0
Heating(Rated)
kW
78.6
84.0
90.0
Heating(Max)
kW
88.2
94.5
100.8
EA
51
54
58
Min.
kW
39.3
42.0
45.0
Max.
kW
102.2
109.2
117.0
Cooling(Rated)
A
53.05
59.62
62.08
Heating(Rated)
A
38.83
41.20
44.76
Cooling(Rated)
A
51.32
57.53
62.08
Heating(Rated)
A
37.86
41.21
43.12
Minimum Ssc
MVA
9.2
10.3
10.4
MCA
A
57.0
64.2
64.0
MFA
A
63
75
75
SEER
W/W
-
-
-
SCOP
W/W
-
-
-
ŋs.c
%
-
-
-
ŋs.h
%
-
-
-
SEER
W/W
-
-
-
SCOP
W/W
-
-
-
ŋs.c
%
-
-
-
ŋs.h
%
-
-
-
kW
42.8
45.3
48
Body
-
GI Steel Plate
GI Steel Plate
GI Steel Plate
Base
-
GI Steel Plate
GI Steel Plate
GI Steel Plate
-
Fin & Tube
Fin & Tube
Fin & Tube
Fin
-
Al
Al
Al
Tube
-
Cu
Cu
Cu
-
Anti-corrosion
Anti-corrosion
Anti-corrosion
-
Inverter Scroll x 2
Inverter Scroll x 2
Inverter Scroll x 2
kW x n
(6.67 x 1) x 1 + (8.93 x 1) x 1 (6.67 x 1) x 1 + (8.93 x 1) x 1
(8.93 x 1) x 2
-
(DS4GR7066FV* x 1) x 1 +
(DS4GM7090FV* x 1) x 1
(DS4GR7066FV* x 1) x 1 +
(DS4GM7090FV* x 1) x 1
(DS4GM7090FV* x 1) x
2
Type
-
PVE
PVE
PVE
Initial charge
cc x n
(1,100 x 1) x 1 + (1,400 x 1) x
1
(1,100 x 1) x 1 + (1,400 x 1) x
1
(1,400 x 1) x 2
-
Propeller
Propeller
Propeller
-
Top
Top
Top
EA
3
3
4
㎥/min
196 x 1 + 303 x 1
196 x 1 + 324 x 1
303 x 2
l/s
3,260 x 1 + 5,052 x 1
3,260 x 1 + 5,401 x 1
5,052 x 2
㎜Aq
11
11
11
Pa
110
110
110
-
BLDC Motor
BLDC Motor
BLDC Motor
W x n
(630 x 1) x 1 + (620 x 2) x 1 (630 x 1) x 1 + (620 x 2) x 1
(620 x 2) x 2
Type
Braze connection
Braze connection
Braze connection
Φ, ㎜ (inch)
19.05 (3/4)
19.05 (3/4)
19.05 (3/4)
Type
Braze connection
Braze connection
Braze connection
Φ, ㎜ (inch)
34.92 (1-3/8)
34.92 (1-3/8)
34.92 (1-3/8)
-
Both liquid and gas pipes
Both liquid and gas pipes
Both liquid and gas pipes
Discharge direction
Quantity
Air Flow Rate
Type
Fin Treatment
Type
Output
Model Name
Outdoor unit module 1
Outdoor unit module 2
Outdoor unit module 3
Outdoor unit module 4
Power Supply
Mode
Performance
HP
Capacity
Maximum number of connectable indoor units
Total capacity of the connected Indoor
Units
Current Input
(Ducted)
Ducted
Type
Material
Pdesignh
Non_Ducted
Current
Current Input
(Non-Ducted)
Current
Efficiency
Casing
Material
Heat
Exchanger
Compressor
Model Name
Oil
Fan
Type
External Static
Pressure
Max.
Fan Motor
Output
Piping
Connections
Liquid Pipe
Gas Pipe
Heat Insulation
Essential