AM160AXVDGH/EU
AM180AXVDGH/EU
AM200AXVDGH1EU
-
-
AM100AXVDGH/EU
-
-
AM100AXVDGH/EU
-
-
-
-
-
-
Piping length (ODU-IDU)
Max. [Equiv.]
m
200[220]
200[220]
200[220]
Piping length
(1st Branch-IDU)
Max.
m
90
90
90
Total piping length
(System)
Max.
m
1,000
1,000
1,000
Level difference
(ODU in highest position)
Max.
m
110
110
110
Level difference
(IDU in highest position)
Max.
m
110
110
110
Level difference
(IDU-IDU)
Max.
m
50
50
50
Min.
㎟
0.75
0.75
0.75
Remark
-
F1, F2
F1, F2
F1, F2
-
Both indoor and outdoor
unit
Both indoor and outdoor
unit
Both indoor and outdoor
unit
-
R410A
R410A
R410A
kg
8.0
8.0
5.5 x 2
tCO
2
e
16.70
16.70
22.97
Cooling
dB(A)
60
61
59
Heating
dB(A)
62
64
63
dB(A)
81
83
81
kg
242
242
185 x 2
kg
259
259
199 x 2
㎜
1,295 x 1,695 x 765
1,295 x 1,695 x 765
(930 x 1,695 x 765) x 2
㎜
1,363 x 1,887 x 829
1,363 x 1,887 x 829
(998 x 1,887 x 829) x 2
℃
-5 ~ 50
-5 ~ 50
-5 ~ 50
℃
-25 ~ 24
-25 ~ 24
-25 ~ 24
Wiring
connections
Transmission
Cable
Power supply intake
Refrigerant
Type
Factory Charging
Net Dimensions (WxHxD)
Shipping Dimensions (WxHxD)
Sound Power
Net Weight
Shipping Weight
Model Name
Outdoor unit module 3
Outdoor unit module 4
Piping
Connections
Outdoor unit module 1
Outdoor unit module 2
Sound
Sound Pressure
External
Dimension
Operating
Temp. Range
Cooling
Heating
Essential
2. Specification
NOTE
•
Specification may be subject to change without prior notice.
•
Specification comply with EN14825 and Eurovent test condition
1) Performances are based on the following test conditions.
-
Cooling : Indoor temperature 27°CDB, 19°CWB, Outdoor temperature 35°CDB, 24°CWB
-
Heating : Indoor temperature 20°CDB, 15°CWB, Outdoor temperature 7°CDB, 6°CWB
-
Equivalent refrigerant pipe length 5m, Level differences 0m
-
Refer to EUROVENT website(www.eurovent-certification.com) for other indoor unit combination and more detail test conditions.
2) Performance of Multiple Module Outdoor unit is weighted average of Single Module outdoor units.
3) Allowed combination ratio of the total rated indoor unit capacity over the rated outdoor unit capacity is 50~130%.
4) Sound pressure level is obtained in an anechoic room.
-
Sound pressure level is a relative value, depending on the distance and acoustic environment.
-
Sound pressure level may differ depending on operation condition.
-
dBA = A-weighted sound pressure level
-
Reference acoustic pressure 0 dB = 20uPa
5) Sound power level is an absolute value that a sound source generates.
-
dBA = A-weighted sound power level
-
Reference power : 1pW
-
Measured according to ISO 3741
6) Sound values of multi combination are theoretical values based on sound results of individual installed units.
7) These products contain R410A (GWP=2,088) which is fluorinated greenhouse gas.
8) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under.
(If the level difference is higher than 50m, make a decision by PDM kit installation Guide software whether the PDM kit should be installed or not.)
-
PDM kit: Pressure Drop Modulation kit
When the outdoor unit is below the indoor unit & the level differences are 40m or more, contact your local dealer for more information.
9)
In case you want to know more information regarding capacity and correction, please refer to capacity table TDB on pvi.samsung.com site.
10)
Recommended combination
* Ducted
* Non-ducted
Capacity
Indoor Units
Capacity
Indoor Units
18HP
AM056ANHPKH×4 + AM071ANHPKH×4
10HP
AM071ANHPKH×4
12HP
AM056ANHPKH×6
14HP
AM056ANHPKH×1 + AM071ANHPKH×5
16HP
AM056ANHPKH×2 + AM090ANHPKH×4
Capacity
Indoor Units
Capacity
Indoor Units
18HP
10HP
12HP
14HP
16HP
AM056AN4PKH×2 + AM090AN4PKH×2
AM028AN4PKH×2 + AM056AN4PKH×2 + AM090AN4PKH×2
AM028 AM045 AM056
AM071 AM090 AM128AN4PKH
AM02 AM045 AM090AN4PKH×3 +
AM128AN4PKH
AM028 AM036 AM045
AM056AN4PKH×2 + AM090AN4PKH×2 + AM128AN4PKH