6-3 Field Wiring
Electrical wiring work
ఐ
W
hen
insta
ll
ing
outdoor
units
in
m
odu
l
e
,
se
l
ect
the
po
w
er
supp
ly
cab
l
e
according
to
the
su
m
of
outdoor
unit
capacit
y
.
(R
efer
to
the
tab
l
e
for
each
m
ode
l)
e
x)
Outdoor
unit
insta
ll
ation
(
AM
1
00FX
W
6
+
AM
1
20FX
W
6
)
ƒ
T
his
de
v
ice
is
intended
for
the
connection
to
a
po
w
er
supp
ly
s
y
ste
m w
ith
a
m
a
x
i
m
u
m
per
m
issib
l
e
s
y
ste
m
i
m
pedance
sho
w
n
in
the
tab
l
e
(
on
the
l
eft
page
)
at
the
interface
point
(
po
w
er
ser
v
ice
bo
x)
of
the
user
’
s
supp
ly
.
ƒ
T
he
user
m
ust
ensure
that
this
de
v
ice
is
connected
on
ly
to
a
po
w
er
supp
ly
s
y
ste
m w
hich
fu
l
fi
ll
s
the
re
q
uire
m
ent
abo
v
e.
If
necessar
y,
the
user
can
as
k
the
pub
l
ic
po
w
er
supp
ly
co
m
pan
y
for
the
s
y
ste
m
i
m
pedance
at
the
interface
point.
ƒ
T
his
e
q
uip
m
ent
co
m
p
l
ies
w
ith
I
E
C
6
1
000
-
3
-1
2
pro
v
ided
that
the
short
-
circuit
po
w
er
Ssc
is
greater
than
or
e
q
ua
l
to
Ssc
(*
2
)
at
the
interface
point
bet
w
een
the
user
’
s
supp
ly
and
the
pub
l
ic
s
y
ste
m
.
It
is
the
responsibi
l
it
y
of
the
insta
ll
er
or
user
of
the
e
q
uip
m
ent
to
ensure
,
b
y
consu
l
tation
w
ith
the
distribution
net
w
or
k
operator
if
necessar
y,
that
the
e
q
uip
m
ent
is
connected
on
ly
to
a
supp
ly w
ith
a
short
-
circuit
po
w
er
Ssc
greater
than
or
e
q
ua
l
to
Ssc
(*
2
)
.
[Ssc (*2)]
Mode
l
Ssc
[
MVA
]
AM0
8
0FX
W
A
66
3.
9
AM
1
00FX
W
A
66
3.
9
AM
1
20FX
W
A
66
4
.
8
AM200FX
W
A
66
7.7
AM300
K
X
W
A
66
11
.5
]
Caution for electrical work
ƒ
Y
ou
m
ust
insta
ll EL
CB
or
MCCB
+ EL
B
- EL
CB
: E
arth
l
ea
k
age
brea
k
er
-
MCCB
:
Mo
l
ded
case
circuit
brea
k
er
- EL
B
: E
arth
l
ea
k
age
brea
k
er
ƒ
Do
not
operate
the
outdoor
unit
before
co
m
p
l
eting
the
refrigerant
pipe
w
or
k
.
ƒ
Do
not
disconnect
or
change
the
cab
l
e
inside
the
product.
It
m
a
y
cause
da
m
age
to
the
product.
ƒ
Specification
of
the
po
w
er
cab
l
e
is
se
l
ected
based
on
fo
ll
o
w
ing
insta
ll
ation
condition
;
cu
lv
ert
insta
ll
ation
/
a
m
bient
te
m
perature
30
°
C
/
sing
l
e
m
u
l
ti
conductor
cab
l
es.
If
the
condition
is
different
fro
m
the
ones
stated
,
p
l
ease
consu
l
t
an
e
l
ectrica
l
insta
ll
ation
e
x
pert
and
re
-
se
l
ect
the
po
w
er
cab
l
e.
-
If
the
l
ength
of
po
w
er
cab
l
e
e
x
ceed
50
m,
re
-
se
l
ect
the
po
w
er
cab
l
e
considering
the
v
o
l
tage
drop.
ƒ
Use
a
po
w
er
cab
l
e
m
ade
out
of
inco
m
bustib
l
e
m
ateria
l
for
the
insu
l
ator
(
inner
co
v
er
)
and
the
sheath
(
outer
co
v
er
)
ƒ
Do
not
use
the
po
w
er
cab
l
e
w
ith
the
core
w
ire
e
x
posed
due
to
insu
l
ator
da
m
age
occurred
during
re
m
o
v
a
l
of
the
sheath.
W
hen
the
core
w
ire
is
e
x
posed
,
it
m
a
y
cause
fire.
Insu
l
ator
(
inner
co
v
er
)
Ex
posed
w
ire
core
Sheath
(
outer
co
v
er
)
Summary of Contents for AM038KXWDCH
Page 168: ...Samsung Electronics 165 5 PBA Diagram and Parts List 5 1 ASS Y PBA MAIN Ŷ Push buttons Type ...
Page 170: ...PBA Diagram and Parts List Samsung Electronics 167 5 1 ASS Y PBA MAIN cont Ŷ DIP S W Type ...
Page 172: ...PBA Diagram and Parts List Samsung Electronics 169 5 2 ASS Y PBA MAIN HUB Ŷ AC ...
Page 174: ...PBA Diagram and Parts List Samsung Electronics 171 5 2 ASS Y PBA MAIN HUB cont Ŷ DC ...