Section 0
Samsung Electronics
3
Contents
5. PCB Diagram and Parts List ......................................................................................................5-1
5-1 Indoor Unit ...............................................................................................................................................................................................................5-1
5-1-1 Slim 1 way cassette type .....................................................................................................................................................................5-1
5-1-2 4way cassette , mini 4way casette type .....................................................................................................................................5-3
5-1-3 Duct type (SLIM Duct 1,2) ..................................................................................................................................................................5-5
5-1-4 Duct type (Slim Duct 3, MA-1(Drain Pump Built-in) ...........................................................................................................5-8
5-1-5 Duct type (MSP, HSP Small, BIG Duct, MA-2(Drain Pump Built-in) .........................................................................5-11
5-1-6 Celing type ...............................................................................................................................................................................................5-17
5-1-7 Big Ceiling .................................................................................................................................................................................................5-19
5-1-8 Wall-Mounted type (Neo Forte)...................................................................................................................................................5-22
5-1-9 Wall Mounted type(A3050, MAX) ...............................................................................................................................................5-24
5-1-10 Wall-Mounted type (Boracay) ....................................................................................................................................................5-27
5-1-11 Floor Stand Type ...............................................................................................................................................................................5-29
5-1-12 OAP DUCT (AM
666
JNESCH/AA) .........................................................................................................................................5-31
5-1-13 Global Duct -1,2 (AM007/009/012/015/018/024/027/030MNMDCH/AA) .....................................................5-36
5-1-14 Global Duct -3 (AM036/048MNMDCH/AA) .......................................................................................................................5-41
5-1-15 Wind-free 1way cassette type ....................................................................................................................................................5-43
5-1-16 360 cassette ..........................................................................................................................................................................................5-48
5-1-17 Indoor Unit Power PCB ..................................................................................................................................................................5-50
5-1-18 18 Display PCB ....................................................................................................................................................................................5-51
6. Wiring Diagram ...........................................................................................................................6-1
6-1 Indoor ..........................................................................................................................................................................................................................6-1
6-1-1 Global 4way(Global Mini-4way) cassteet type .....................................................................................................................6-1
6-1-2 Slim 1way cassette type .....................................................................................................................................................................6-2
6-1-3 BIG Duct .......................................................................................................................................................................................................6-3
6-1-4 Ceiling ...........................................................................................................................................................................................................6-4
6-1-5 Big Ceiling (AM036/048JNCDCH/AA) ........................................................................................................................................6-5
6-1-6 RAC(Neo Forte) ........................................................................................................................................................................................6-6
6-1-7 Wall Mounted type(A3050, MAX) .................................................................................................................................................6-7
6-1-8 DUCT type (Slim Duct 3, MA-1(Drain Pump Built-in)) ......................................................................................................6-8
6-1-9 DUCT type (Slim Duct 1,2, MSP)....................................................................................................................................................6-9
6-1-10 DUCT type (HSP Small , MA-2(Drain Pump Built-in)) ..................................................................................................6-10
6-1-11 Floor Stand Type ...............................................................................................................................................................................6-11
6-1-12 OAP Duct type ...................................................................................................................................................................................6-12
6-1-13 Wall-Mounted type (Boracay) ....................................................................................................................................................6-13
6-1-14 Global Duct (AM007/009/012/015/018/024/027/030MNMDCH/AA) .............................................................6-14
6-1-15 Global Duct (AM036/048MNMDCH/AA) ...........................................................................................................................6-15
6-1-16 Wall-Mounted type Wind-free 1way cassette type .......................................................................................................6-16
6-1-17 Wind-free 1way cassette type ....................................................................................................................................................6-17
6-1-18 360 cassette ..........................................................................................................................................................................................6-18
7. Reference Sheet ..........................................................................................................................7-1
7-1 Index for Model Name ......................................................................................................................................................................................7-1
7-1-1 Indoor Unit ..................................................................................................................................................................................................7-1
7-1-2 Panel ................................................................................................................................................................................................................7-2
7-2 Pump-down Method.........................................................................................................................................................................................7-3
7-2-1 Precautions for Pump-down ............................................................................................................................................................7-3
7-2-2 For Single Installation of Outdoor Unit (Only One Outdoor Unit Installed) .........................................................7-3
7-2-3 When Two or More Outdoor Units are Installed ...................................................................................................................7-3
7-3 How to Put Refrigerant in Refrigerant Container ..............................................................................................................................7-4
7-3-1 How to put refrigerant in container before pump-down ..............................................................................................7-4