31
English
Appendix
The table below indicates the temperature and humidity ranges the air conditioner can be
operated within. Refer to the table for efficient use.
MODE
OPERATIONAL TEMPERATURE
INDOOR
HUMIDITY
IF OUT OF CONDITIONS
INDOOR
OUTDOOR
Cool
18 ˚C to 32 ˚C
Depends
on the
specifications
of the outdoor
unit.
80 % or less
Condensation may occur on
the indoor unit with risk to
have either water blow off or
drops on the floor.
Heat
27 ˚C or less
-
Internal protection triggers
and the air conditioner will
stop.
Dry
18 ˚C to 32 ˚C
80 % or less
Condensation may occur on
the indoor unit with risk to
have either water blow off or
drops on the floor.
NOTE
• The standardized temperature for heating is 7 ˚C. If the outdoor temperature drops to 0 ˚C or
below, the heating capacity can be reduced depending on the temperature condition.
• If the cooling operation is used at over 32˚C (indoor temperature), it does not cool at its full
capacity.
Operation Ranges