E-
42
DHW tank (Continued)
System configuration
X
For the reliable performance and durability, all parts as listed below ,including a relief valve, an
expansion vessel, a drain valve and pressure reducing valve , should be installed according to each
national or regional standards. They are not supplied by SAMSUNG.
- Pressure relief valve (9 bar)
- Expansion vessel (pre-charge pressure = 8 bar)
- Drain valve (manual type)
-
Tundish
- Expansion relief valve
- Pressure reducing valve
X
Screw the thermistor socket in the foreseen threaded thermistor hole in the tank, use a thread sealant
such as Teflon or similar to make water tight.
X
Apply contact glue to the thermistor and insert the thermistor as deep as possible in the thermistor
socket. Fix using the nut provided.
Summary of Contents for AEN080YDEHA
Page 1: ......
Page 11: ...E 11 ENGLISH Dimensional drawing 131 7 78 5 103 7 104 0 125 0 490 22 0 39 2 850 0 510 0 314 6 ...
Page 22: ...E 22 Wiring diagram AEN160YDGHA Wiring work Continued ...
Page 23: ...E 23 ENGLISH Wiring diagram AEN160YDEHA AEN080YDEHA ...
Page 38: ...E 38 DHW tank Continued Accessories Leg 3 Anode bar 1 Conduit 1 ...
Page 48: ......