6
Installation Procedure
English
Ins
tallation Pr
oc
edur
e
• Construct a protection wall with a solid material such
as concrete to block the sea breeze. Make sure that the
height and the width of the wall are 1.5 times larger
than the size of the outdoor unit. Also, secure a space
larger than 700 mm between the protection wall and
the outdoor unit for exhausted air to ventilate.
Protection wall
Outdoor Unit
Sea breeze
Sea
CAUTION
• Depending on the condition of power supply, unstable
power or voltage may cause malfunction of the parts
or control system. (At the ship or places using power
supply from electric generator...etc)
• Install the unit in a place where water can drain smoothly.
• If you have any difficulty finding installation location as
prescribed above, contact your manufacturer for details.
• Be sure to clean the sea water and the dust on the
heat exchanger of the outdoor unit and apply a
corrosion inhibitor on it. (At least once in a year.)
Outdoor unit dimensions
A Type
AC140KXAPEH/SA, AC125KXAPEH/SP
620
330
384
360
1420
1395
940
567
558
1095
Electrical
component box
B Type
AC100KXAPEH/SA, AC125KXAPEH/SA
AC100KXADGH/SA, AC140KXADGH/SA
620
330
384
360
1210
1185
940
567
558
675
Electrical
component box
C Type
AC071KXAPEH/SA, AC071KXADEH/SA
880
53
310
660
364
18
798
Minimum clearances for the outdoor unit
When installing 1 outdoor unit
(Unit: mm)
300 or mor
e
1500 or mor
e
300 or
more
600 or
more
300 or
mor
e
2000
or more
1500
or mor
e
600
or mor
e
300
or more
1500
or mor
e
300 or
mor
e
When installing more than 1 outdoor unit
(Unit: mm)
1500
or more
600
or more
3000
or more
3000
or more
300
or more
600
or more
600
or more
1500 or mor
e
300
or mor
e
360_AC_Outdoor_AU_Eng_EN.indb 6