Installation Procedure
English
Option
SEG17
SEG18
SEG19
SEG20
Explanation
Buzzer control
Number of hours using filter
PAGE
control of a remote controller
Indication
and Details
Indication
Details Indication
Details
Indication
Details
Indication
Details
0
Use of
buzzer
2
1000 Hour
3
0 or 1
Indoor 1
1
Non
use of
buzzer
6
2000 Hour
2
Indoor 2
3
Indoor 3
4
Indoor 4
Option
SEG21
SEG22
SEG23
-
Explanation
Heating setting
compensation
RESERVED
Away Set OFF Timer
-
Indication
and Details
Indication
Details
Indication
Details
-
0
Disuse
0 or 1
Auto Set OFF 30Min.
-
1
2°C
2
Auto Set OFF 60Min.
2
5°C
3
Auto Set OFF 120Min.
4
Auto Set OFF 180Min.
5
Press the
button to save and complete the option setting.
6
Press the
button to exit to normal mode.
•
Level control : The centralized controller can limit the functions and inputs of connected products with this function
enabled. [ Example: Operation mode limit (Cooling only/Heating only/No limitation), Heating
temperature upper limit, Cooling temperature lower limit ] To enable 'Level control' when applying
the DPM with the centralized controller, appoint the master (Set 'Use of external control [SEG14]
option to 4 or higher).
– Example : When installing DPM ( 1 Outdoor unit with 4 indoor units)
Condition
SEG 14 Setting
Result
External control
Level control
Indoor 1
Indoor 2
Indoor 3
Indoor 4
Default
Not set (0)
Slave (All)
Disuse
Use
4
Not set (0)
Not set (0)
Not set (0)
Master (Indoor 1), Slave (Indoor 2,3,4)
Use (Indoor 3)
Disuse
Not set (0)
Not set (0)
1~3
Not set (0)
Slave (All)
Use (Indoor 4)
Use
Not set (0)
Not set (0)
Not set (0)
5~7
Master (Indoor 4), Slave (Indoor 1,2,3)
NOTE
•
Press
button anytime during setup to exit without setting.
•
Option code will not be applied if you don't press
button.
•
Setting Installation option code is available only with a master wired remote controller.
•
Setting Installation option code is available when there is one on one connection between a wired remote
controller and an indoor unit.