After tube contraction work is completed, wrap it with
the insulation tape to finish.
Insulation tape
CAUTION
•
Make sure that the connection parts are not exposed
to outside.
•
Be sure to use insulation tape and a contraction tube
made of approved reinforced insulating materials that
have the same level of withstand voltage with the
power cable. (Comply with the local regulations on
extensions.)
WARNING
•
In case of extending the electric wire, please DO NOT
use a round-shaped Pressing socket.
– Incomplete wire connections can cause electric shock
or a fire.
Step 16 Setting additional functions
of wired remote control
Automatic Air-Volume (only for AC
MN
DKH)
When DPM is installed, Automatic Air-Volume function
cannot be performed simultaneously for all indoor units.
Automatic Air-Volume function must be performed for
each indoor unit with the wired remote control attached.
With its BLDC motor, you can use smart adjust the indoor
unit fan speed depending on the installation condition.
If the external static pressure is high so that the duct
becomes longer or if the external static pressure is low
so that the duct becomes shorter, Using the Automatic
Air-Volume function,the volume of exhaust air has been
adjusted to the rated volume flow rate automatically.
Main Menu Sub-menu
1 2 3
5
4
6
SEG Used
Performing the Automatic Air-Volume function.
•
Check the air conditioning unit stop.
Press the Power button to stop the air conditioner
•
Go to Service setting mode with remote controller.
1
Press the
and
buttons at the same time for more
than 3 seconds and then a Main menu will be displayed.
2
Press the
/
button to select and then press
button to enter a Sub-menu setting screen.
3
Press the
/
button to select and then press
button to enter a automatic air-volume setting screen.
4
Press the
/
button to select 1 to enable automatic
air-volume operation.
5
Select mode No. 8.2 , and set to “1”.
6
Press the
/
button to select 3 and then press
button to enter input voltage.
7
Press the
/
button to select 1~3 to set voltage.
(1 : 220V, 2 : 230V, 3 : 240V)