37
English
Appendix
COMMISSION DELEGATED REGULATION (EU) No 626/2011
i)
PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS)
ii)
A
Supplier's name
-
Samsung Electronics Co,, Ltd,
B
Model name (Indoor/Outdoor)
-
AC100RN4DKG/
AC100RXADKG
AC100RN4DKG/
AC100RXADNG
AC120RN4DKG/
AC120RXADKG
AC120RN4DKG/
AC120RXADNG
AC100RN4PKG/
AC100RXADKG
AC100RN4PKG/
AC100RXADNG
C
Sound Power Level (Indoor/Outdoor)
dB(A)
61 / 69
61 / 69
61 / 70
61 / 70
61 / 69
61 / 69
D
Refrigerant name
1)
-
R-32
R-32
R-32
R-32
R-32
R-32
E
GWP
-
675
675
675
675
675
675
F
SEER
-
7,0 7,0 6,0 6,0 6,8 6,8
G
Energy efficiency class (SEER)
-
A++
A++
A+
A+
A++
A++
H
Q
CE
2)
(cooling season)
kWh/a
iii)
500 500 700 700 515 515
I
Pdesignc
kW
10,0 10,0 12,0 12,0 10,0 10,0
J
SCOP (Average)
-
4,3 4,3 4,0 4,0 4,3 4,3
K
Energy efficiency class SCOP (Average)
-
A+
A+
A+
A+
A+
A+
L
Q
HE
3)
heating season (Average)
kWh/a
iii)
1726 1726 2275 2275 1726 1726
M
Pdesignh (Average)
kW
5,3 5,3 6,5 6,5 5,3 5,3
N
Back up heating capacity(Average)
kW
0 0 0 0 0 0
O
Declared capacity (Average)
kW
5,3 5,3 6,5 6,5 5,3 5,3
P
Other heating seasons suitable for use
-
'-iv)
Q
SCOP (Warmer)
-
-
-
-
-
-
-
R
Energy efficiency class SCOP (Warmer)
-
-
-
-
-
-
-
S
Q
HE
3)
heating season (Warmer)
kWh/a
iii)
-
-
-
-
-
-
T
Pdesignh (Warmer)
kW
-
-
-
-
-
-
U
Back up heating capacity (Warmer)
kW
-
-
-
-
-
-
V
Declared capacity (Warmer)
kW
-
-
-
-
-
-
W
SCOP (Colder)
-
-
-
-
-
-
-
X
Energy efficiency class SCOP (Colder)
-
-
-
-
-
-
-
Y
Q
HE
3)
heating season (Colder)
kWh/a
iii)
-
-
-
-
-
-
Z
Pdesignh (Colder)
kW
-
-
-
-
-
-
AA
Back up heating capacity (Colder)
kW
-
-
-
-
-
-
AB
Declared capacity (Colder)
kW
-
-
-
-
-
-
1
Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would
contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to [675]. This means that if 1 kg of this
refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be [675] times
higher than 1 kg of CO
2
, over a period of 100 years.
Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always
ask a professional.
2
Energy consumption “XYZ” kWh per year, based on standard test results.
Actual energy consumption will depend on how the appliance is used and where it is located.
3
Energy consumption “XYZ” kWh per year, based on standard test results. Actual energy consumption will depend
on how the appliance is used and where it is located.