12
English
Outdoor unit installation
The outdoor unit must be installed on a rigid and stable base to avoid any increase in the noise level and vibration,
particularly if the outdoor unit is to be installed in a location exposed to strong winds or at a height, the unit must be fixed to
an appropriate support(wall or ground).
Fix the outdoor unit with anchor bolts.
NOTE
• The anchor bolt must be 20mm or higher from the base surface.
(Unit : mm)
620
940
330
360
384
Anchor bolt hole
660
880
310
340
364
Anchor bolt hole
Type A,B,C: AC030MXQFEC / AC036MXQFEC
AC042MXQFEC / AC048MXQFGC
AC060MXQFGC
Type D,E : AC018MXQFEC / AC024MXQFEC
543
790
285
319
343
Anchor bolt hole
Type F : AC012MXQFEC
CAUTION
• Make a drain outlet around the base for outdoor unit drainage.
• If the outdoor unit is installed on the roof, you have to check the ceiling strength and waterproof the unit.
Location of the compressor
• Make sure that product is level during installation. Especially, product shouldn’t be tilted towards the
compressor.
CAUTION