![Samsung AC-505CM Series Installation Manual Download Page 35](http://html.mh-extra.com/html/samsung/ac-505cm-series/ac-505cm-series_installation-manual_18179035.webp)
03
O
THERS
35
English
Packing and unpacking guide
Outdoor unit
f
Packing the unit as below procedure
1. Fix the outdoor unit and the wood palette by 4 screws.
2. Put the cushion-top onto the outdoor unit.
3. Put the packing case from the top of set.
4. Seal the packing case.
f
Unpacking the unit as below procedure
1. Take out the packing case from the set.
2. Take out the cushion-top.
3. Unscrew 4 screws from the wood palette and then move the set.
MODEL
AC012MXQFEC
AC018MXQFEC
AX024MXQFEC
CLIMATES CLASS
T1
T3
T1
T3
T1
T3
RATED CAPACITY
COOLING
12000 Btu/h
10200 Btu/h
18000 Btu/h
15300 Btu/h
21000 Btu/h
18700 Btu/h
3.52 kW
2.99 kW
5.28 kW
4.48 kW
6.15 kW
5.48 kW
HEATING
-
-
-
RATED VOLTAGE & FREQUENCY
220 - 240 V ~ 50 Hz
220 - 240 V ~ 50 Hz
220 - 240 V ~ 50 Hz
RATED CURRENT
COOLING
4.7A
5.6A
6.9A
8.2A
8.0A
10.0A
HEATING
-
-
-
RATED POWER
INPUT
COOLING
1.0 kW
1.2 kW
1.5 kW
1.8 kW
1.75 kW
2.2 kW
HEATING
-
-
-
EER/COP
COOLING
12.0(Btu/h)/W
8.5(Btu/h)/W
12.0(Btu/h)/W
8.5(Btu/h)/W
12.0(Btu/h)/W
8.5(Btu/h)/W
HEATING
-
-
-
POWER FACTOR
COOLING
0.92
0.94
0.95
0.96
0.95
0.97
HEATING
-
-
-
MAX CURRENT
11.5A
20.5 A
20.5 A
DESIGN PRESSURE
H:4.1 Mpa, L:1.4 Mpa
H:4.1 Mpa, L:1.4 Mpa
H:4.1 Mpa, L:1.4 Mpa
ANNUAL ENERGY
CONSUMPTION
for 2,000Hr
-
-
-
-
-
-
for 2,700Hr
2700 kWh
3240 kWh
4050 kWh
4860 kWh
4725 kWh
5940 kWh
REFRIGERANT
R-410A 0.8kg
R-410A 0.9kg
R-410A 1.1kg
IP NUMBER
IPX4
IPX4
IPX4
NET WEIGHT
29.0 kg
37.0 kg
46.5 kg
DIMENSIONS OF THE UNIT
[W×H×D]
790*548*285
880*638*310
880*798*310
COUNTRY OF ORIGIN
MADE IN KOREA
MADE IN KOREA
MADE IN KOREA
Product specification
Summary of Contents for AC-505CM Series