5-10
EB 8484-1 EN
Installation
The positioner is attached to the control valve
using a NAMUR bracket (10).
1. Seal the signal pressure output at the
back of the positioner with the screw
plug (4, order no. 0180-1254) and the
associated O-ring (order no. 0520-
0412) if the screw plug is not yet in
place.
2. Screw the two bolts (14) to the bracket
(9.1) of the stem connector (9), place the
follower plate (3) on top and use the
screws (14.1) for fastening.
Actuator sizes 2800 cm² and 1400 cm²
with 120 mm travel:
−
For a travel of 60 mm or smaller,
screw the longer follower plate (3.1)
directly to the stem connector (9).
− For a travel exceeding 60 mm, mount
the bracket (16) first and then the fol
-
lower plate (3) to the bracket togeth-
er with the bolts (14) and screws
(14.1).
3.
Mount NAMUR bracket (10) to the con
-
trol valve as follows:
−
For
attachment to the NAMUR rib
,
use an M8 screw (11) and toothed
lock washer directly in the yoke hole.
−
For attachment to
valves with rod-
type yokes
, use two U-bolts (15)
around the yoke. Align the NAMUR
bracket (10) according to the em-
bossed scale so that the follower
plate (3) is shifted by half the angle
range to the NAMUR bracket (the
slot of the follower plate is centrally
aligned with the NAMUR bracket at
mid valve travel).
4. Mount connecting plate (6) or pressure
gauge bracket (7) with pressure gauges
(8) on the positioner. Make sure that the
two seals (6.1) are seated properly.
5.
Select required lever size (1) M, L or XL
and pin position according to the actua-
tor size and valve travel listed in the trav-
el table on page 5-4.
Should a pin position other than position
35
with the standard
M
lever be required or an
L
or
XL
lever size be required, proceed as
follows:
6. Fasten the follower pin (2) in the as-
signed lever hole (pin position as speci-
fied in the travel table). Only use the lon
-
ger follower pin (2) included in the
mounting kit.
7. Place the lever (1) on the shaft of the po-
sitioner and fasten it tight using the disk
spring (1.2) and nut (1.1).
Move lever once all the way as far as it
will go in both directions.
8. Place positioner on the NAMUR bracket
in such a manner that the follower pin
(2) rests in the slot of the follower plate
(3, 3.1). Adjust the lever (1) correspond-
ingly.
Screw the positioner to the NAMUR
bracket using its two fastening screws.
10
11
1
1
14.1
3
3.1
16
15
14
1
1.2
1.1
2
9.1
9
6.1
6
7
8
Attachment to rod-type yoke
Rods with 20 to 35 mm diameter
Attachment to NAMUR rib
Additional bracket
for actuators with
2800 cm² and travel
≥ 60 mm
XL and L lever
1
Lever
1.1 Nut
1.2 Disk spring
2
Follower pin
3
Follower plate
3.1 Follower plate
6
Connecting plate
6.1 Seals
7
Pressure gauge bracket
8
Pressure gauge
mounting kit
9
Stem connector
9.1 Bracket
10
NAMUR bracket
11
Screw
14
Bolt
14.1 Screws
15
U-bolt
16
Bracket
Fig. 5-10:
Attachment according to IEC 60534-6 (NAMUR)
Summary of Contents for TROVIS 3730-1
Page 6: ...6 EB 8484 1 EN...
Page 14: ...1 8 EB 8484 1 EN...
Page 18: ...2 4 EB 8484 1 EN...
Page 72: ...5 38 EB 8484 1 EN Installation 32 31 Fig 5 30 Terminal assignment of position transmitter...
Page 78: ...5 44 EB 8484 1 EN...
Page 82: ...6 4 EB 8484 1 EN...
Page 98: ...8 6 EB 8484 1 EN...
Page 108: ...11 2 EB 8484 1 EN...
Page 110: ...12 2 EB 8484 1 EN...
Page 112: ...13 2 EB 8484 1 EN...
Page 114: ...14 2 EB 8484 1 EN...
Page 118: ...15 4 EB 8484 1 EN...
Page 119: ...EB 8484 1 EN 15 5...
Page 120: ...15 6 EB 8484 1 EN...
Page 121: ...EB 8484 1 EN 15 7...
Page 122: ...15 8 EB 8484 1 EN...
Page 123: ...EB 8484 1 EN 15 9...
Page 124: ...15 10 EB 8484 1 EN...
Page 125: ...EB 8484 1 EN 15 11...
Page 126: ...15 12 EB 8484 1 EN...
Page 127: ...EB 8484 1 EN 15 13...
Page 128: ...15 14 EB 8484 1 EN...
Page 129: ...EB 8484 1 EN 15 15...
Page 130: ...15 16 EB 8484 1 EN...
Page 131: ...EB 8484 1 EN 15 17...
Page 132: ...15 18 EB 8484 1 EN...
Page 133: ...EB 8484 1 EN 15 19...
Page 134: ...15 20 EB 8484 1 EN...
Page 142: ...16 8 EB 8484 1 EN...
Page 143: ......