For the following products 

Temperaturregler mit/ohne Sicherheits-

temperaturwächter oder -begrenzer 

 

Temperature regulators with/without 

safety temperature monitors/limiters 

 

 

 

Nach der Zündgefahrenbewertung nach 

DIN EN 13463-1 wird hiermit bestätigt, dass die 

oben angegebenen Regler ohne Hilfsenergie keine 

eigene potenzielle Zündquelle besitzen und damit 

nicht der Gerätedefinition nach der Richtlinie 

2014/34/EU entsprechen. 

 

According to the ignition risk assessment based 

on DIN EN 13463-1, we hereby certify that the 

self-operated regulators mentioned above do not 

have their own potential ignition source, and as a 

result, they are not classified as “equipment” in 

the sense of Directive 2014/34/EU. 

Die Geräte fallen damit nicht unter die Richtlinie 

2014/34/EU und können somit auch nicht als Ge-

räte nach dem Verfahren der EG-

Baumusterprüfung nach Anhang III der Richtlinie 

zertifiziert werden. 

 

Since the devices do not fall within the scope of 

Directive 2014/34/EU, they cannot be certified as 

"equipment" according to the EC type examina-

tion procedure specified in Annex III of the Di-

rective. 

Diese Erklärung gilt für die Gerätetypen nach Ta-

belle 1 die entsprechend den bausatzmäßigen 

Unterlagen gefertigt sind. 

 

This declaration applies to the device types listed 

in Table 1 manufactured in compliance with the 

production documents. 

 

 

 

Begründung: 

 

Reason:

 

Die vorgenannten nichtelektrischen RoH-

Ausführungen haben nach der Zündgefahrenbe-

wertung, entsprechend DIN EN 13463-1, Absatz 

5.2 auch bei selten auftretenden Betriebsstörun-

gen keine eigene potenzielle Zündquelle und fallen 

somit 

nicht

 unter die Richtlinie 2014/34/EU 

 

According to the ignition risk assessment per-

formed in accordance with DIN EN 13463-1, sec-

tion 5.2, the non-electrical self-operated regulator 

versions do not have their own potential ignition 

source even in the rare incident of an operating 

fault. As a result, they 

do not

 fall within the scope 

of Directive 2014/34/EU. 

 

 

 

Hinweis:

 

 

Note: 

Diese Erklärung gilt für den Einsatz der genannten 

Betriebsmittel nur in den Ausführungen 

ohne 

elektrische Komponenten

 für allgemeine techni-

sche Anwendungen innerhalb des Ex-Bereiches. 

 

This declaration applies to the use of the men-

tioned device versions 

without electrical com-

ponents only

 for general technical applications 

in hazardous areas. 

Die Verwendung als Komponenten nach der Defi-

nition der Richtlinie 2014/34/EU wird ausdrücklich 

ausgeschlossen. 

 

The use as "components" as defined by Directive 

2014/34/EU is explicitly prohibited. 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for 2439

Page 1: ...Translation of original instructions EB 2185 EN Edition August 2018 Type 2439 Safety Temperature Limiter STL...

Page 2: ...fter sales Service Department aftersalesservice samson de The mounting and operating instructions for the devices are included in the scope of delivery The latest documentation is available on our web...

Page 3: ...ounting and start up 23 5 1 Assembling the safety temperature limiter and valve 23 5 2 Additional fittings 24 5 3 Temperature sensor and capillary tube 25 5 4 Electric signal transmitter 26 5 4 1 Retr...

Page 4: ...Contents 4 EB 2185 EN 9 Appendix 35 9 1 After sales service and spare parts 35 9 2 Tightening torques 35 9 3 Certificates 35...

Page 5: ...ty for damage resulting from the failure to use the de vice for its intended purpose or for damage caused by external forces or any other external factors Refer to the technical data and nameplate for...

Page 6: ...y must observe all haz ard statements warning and caution notes in these mounting and operating instructions es pecially for installation start up and service work We also recommend checking the hazar...

Page 7: ...tion 5 2 even in the rare incident of an operating fault Therefore such valve versions do not fall within the scope of Directive 2014 34 EU For connection to the equipotential bonding system observe t...

Page 8: ...es on possible personal injury WARNING Risk of personal injury due to residual process medium in the valve While working on the valve residual process medium can escape and depending on its properties...

Page 9: ...of irreparable regulator damage caused by the regulator components being taken apart The safety temperature limiter is an inseparable hydraulic unit consisting of a safety thermostat capillary tube an...

Page 10: ...e to excessively high or low tightening torques The connection between valve and safety temperature limiter must be tightened with a certain tightening torque Excessively tightened torques lead to par...

Page 11: ...rmation Valve Mounting and operating instructions Type 2431 for Type 43 1 u EB 2171 Type 2432 for Type 43 2 Type 2433 for Type 43 3 u EB 2173 Type 2435 for Type 43 5 u EB 2172 Type 2436 for Type 43 6...

Page 12: ...set point adjuster 8 This limit value is indicated on the scale 11 The valve is locked by a spring mechanism when the temperature reaches the adjustable limit when the capillary tube ruptures or there...

Page 13: ...elding ends optional 2 Valve seat 3 Plug 4 Plug stem 5 Plug spring 8 Operating element with set point adjuster 10 Capillary tube 11 Scale 12 Temperature sensor 13 Thermowell 15 Coupling nut 16 Opening...

Page 14: ...tall the sensor together with the supplied thermowell When the safety temperature limiter is com bined with a Type 2430 Control Thermostat make sure that there is a minimum difference of approximately...

Page 15: ...adjusted limit Permissible pressure at the sensor with thermowell 40 bar Capillary tube length 2 m 5 m Switching cycles according to DIN EN 14597 500 Electric signal transmitter Max load 230 V 16 A wi...

Page 16: ...36 2439 Height H 180 180 Height H1 30 50 Type 2431 2439 kg approx 1 9 2 0 2 1 2 0 2 1 2 3 Type 2433 2439 kg approx 2 1 2 2 2 3 Type 2435 2439 kg approx 2 4 2 5 2 6 Type 2436 2439 kg approx 2 3 2 4 2 5...

Page 17: ...t H1 95 Type 2437 2439 Height H 255 305 Height H1 30 55 Table 5 Male thread Weights in kg Type 2432 2439 Type 2433 2439 Type 2436 2439 and Type 2437 2439 Valve size DN 15 20 25 32 40 50 Valve body CC4...

Page 18: ...ht H 180 230 Type 2437 2439 Height H 260 310 Valve body 1 4408 A351 CF8M 2 Type 2432 2439 Height H 180 180 Type 2436 2439 Height H 180 180 1 With screwed on flanges 2 With flanged body Table 7 Flanges...

Page 19: ...DN 32 to 50 Type 2439 Height H4 130 Length L5 185 Length B 210 Length B1 190 G G M M32x1 5 T 12 Type 2430 Height H6 130 Length L5 185 220 G G G T 12 19 Type 2439 kg approx 1 2 Type 2430 kg approx 0 9...

Page 20: ...h threaded ends 2433 2439 With screwed on flanges H1 L H L H H1 L1 L H H1 d SW L2 L H H1 A SW 2435 2439 Female thread 2436 2439 Female thread 2436 2439 With welding ends 2436 2439 With threaded ends L...

Page 21: ...ign and principle of operation Dimensional drawings B H4 B1 G L5 T M M SW34 SW22 SW17 G L5 T H6 Type 2439 Safety Temperature Limiter Type 2430 2439 Control Thermostat with STL Fig 3 Dimensional drawin...

Page 22: ...uctions Protect the device against external influ ences e g impact Protect the device against moisture and dirt Note Observe the permissible ambient tem peratures see section 3 2 4 3 Storage Risk of d...

Page 23: ...ficient heat dissipation when components are insulated Do not include the safety temperature limiter in the insulation of the pipeline 5 1 Assembling the safety tem perature limiter and valve See Fig...

Page 24: ...e 1 NI Strainer is suitable u T 1010 The following points must be observed during installation of the strainer Do not use the strainer to permanently filter the process medium Install the strainer ups...

Page 25: ...d filling the free space between sen sor and thermowell with oil or when in stalled horizontally with grease or any other heat transfer medium This prevents heat transfer delays Observe the ther mal e...

Page 26: ...20 Black Brown unlocked Blue locked 5 5 Start up Risk of burn injuries due to hot or cold com ponents and pipelines Depending on the process medium valve components and pipelines may get very hot or...

Page 27: ...flow velocities Before the full capacity is reached drain off the start up condensate Make sure that the air contained in the plant escapes as quickly as possible Open the shut off valves slowly prefe...

Page 28: ...ontinuously adjustable A turn corresponds to approx 3 2 K or 3 9 K de pending on the limit range see Table 9 6 1 2 Adjusting the tempera ture limit using a heating bath If the temperature limit of the...

Page 29: ...ol Thermostat or double adapter is used screw it onto the safety temperature limiter 14 Make sure the minimum temperature dif ference is observed for the TR STL When the safety temperature limiter is...

Page 30: ...after a fault A red cam visible in the opening 16 in Fig 2 indicates that the valve is locked After the fault has been remedied a screw driver is required to unlock the safety tem perature limiter Fig...

Page 31: ...low tightening torques The connection between valve and safety temperature limiter must be tightened with a certain tightening torque Excessively tight ened torques lead to parts wearing out quicker...

Page 32: ...listed in Table 10 are caused by mechanical faults and incorrect regulator sizing In the simplest case the functioning can be restored following the recommended action Special tools may be required fo...

Page 33: ...r installed in the wrong location Install the temperature sensor into the pipeline in such a way that the heat flow is correctly mea sured Valve or KVS CV coefficient too small Check the sizing Change...

Page 34: ...Wear protective clothing and safety gloves DANGER WARNING 8 1 Decommissioning To decommission the safety temperature lim iter before removing it proceed as follows Steps 1 to 6 only apply when the th...

Page 35: ...te u www samson de or in all SAMSON product catalogs To assist diagnosis and in case of an unclear mounting situation specify the following details so far as possible See section 2 Device type Model n...

Page 36: ...of 15 May 2014 EG Baumusterpr fbescheinigung EC Type Examination Certificate Modul B Module B Zertifikat Nr Certificate no 01 202 931 B 11 0016 Angewandtes Konformit tsbewertungsverfahren Conformity a...

Page 37: ...einschl gigen Harmonisierungsrechtsvorschriften der Union best tigt the conformity with the relevant Union harmonisation legislation is declared with est conforme la l gislation d harmonisation de l...

Page 38: ...cording to the EC type examina tion procedure specified in Annex III of the Di rective Diese Erkl rung gilt f r die Ger tetypen nach Ta belle 1 die entsprechend den bausatzm igen Unterlagen gefertigt...

Page 39: ...EB 2185 EN 39...

Page 40: ...2018 10 26 English SAMSON AKTIENGESELLSCHAFT Weism llerstra e 3 60314 Frankfurt am Main Germany Phone 49 69 4009 0 Fax 49 69 4009 1507 samson samson de www samson de EB 2185 EN...

Reviews: