background image

HDV

Routing switchers

Sams elektronik d.o.o. • [email protected] • www.sams.rs

elektronik

19

ICONS
 

  OPEN: Load status of matrix

 

  SAVE: Save status of matrix

 

  PROPERTIES: Configure the com port and selects type of signal that will be controlled

 

  LOCK PANEL: Locks software

 

  UNDO: Returns a step backward state of matrix for the selected destination

 

  LOCK: Locks destination

 

  VIDEO: Controls whether this kind of signal interconnect

 

  AUDIO 1 (AUDIO 1 - AUDIO2): Controls whether this kind of signal interconnect

 

  AUDIO 2 (DATA): Controls whether this kind of signal interconnect

 

  SOURCE NAME: Name of input

 

  DESTINATION NAME: Name of output

SOFTWARE

At start, there will be an indicator of communication with the master command. If communication is 

realized, at the intersection of XY axes are displayed connections as icons:

VIDEO:

AUDIO 1 (AUDIO 1 - AUDIO 2):         - red icon

AUDIO 2 (DATA):         - green icon

If the indicator of communication retain more than one minute:

1. The communication parameters are not set

2. The main remote control is not powered on or connected to a PC.

GETTING STARTED

Software RS-6464 is designed to control the matrix. It has the same features as the master command. 

The advantage of the software is that the status of the matrix can be seen at the same time for all 

connections in the form of intersection of X and Y axes.

Start the program.

indicator of communication

Summary of Contents for HDV-3232

Page 1: ... Updated 26 november 2014 Z10 3 edition 1 Code 003 641 ENGLISH Sams elektronik d o o 48 Zivka Davidovica st 11050 Belgrade Serbia Tel Fax 381 11 3806 253 381 11 2402 212 sams sams rs www sams rs Read the instructions before using the device Keep this manual for periodic usage USER MANUAL FOR USE AND MAINTENANCE ...

Page 2: ...cturer servicer has not completed repair or replacement within a reasonable time or if the manufacturer servicer did not perform repair or replacement without significant inconvenience to the consumer 5 The consumer may not terminate the contract if the lack of conformity of the product is negligible 6 The product will function properly when used in accordance with the user manual 7 Period of serv...

Page 3: ...ightning in a triangle is to alert the user to the presence of high voltage In poor conditions the user may be exposed to shock The symbol exclamation mark in a triangle is to alert the user to comply by the terms of use in user s manual which is supplied with the device SAFETY WARNINGS ELECTRICAL SHOCK HAZARD DO N OT O PEN CAUTION RIZIK OD S TRUJNOG UDARA NE O TVARATI DOK JE P OD N APONOM UPOZORE...

Page 4: ...evice is equipped with a protective fuse in the power outlet Do not bypass fuse 12 Do not replace the fuse Replacement can be made by a person authorized by the manufacturer 13 Do not bend the power cord so that it can be damaged 14 Connect connectors as in the enclosed instructions Deviations from the allowed values predicted for the inputs and outputs of the device can cause severe damage and wa...

Page 5: ...1 8 CP 3232 MASTER REMOTE CONTROL 32X32 9 CP 32 SLAVE REMOTE CONTROL 32X1 10 CONFIGURATION AND CONNECTION GRAPHIC EXAMPLE 11 CONNECTORS 12 ADDRESSING REMOTE CONTROLS 12 NETWORK SETUP 13 NETWORK ACCESS AND DEVICE CONTROL 13 PROBLEMS AND SOLUTIONS IN A NETWORK ENVIRONMENT 15 SOFTWARE SUPPORT 17 SOFTWARE 18 CONFIGURATION SOFTWARE FOR SLAVE COMMANDS 23 NOTES 28 Page Description TABLE OF CONTENTS ...

Page 6: ...m dust Package it in a box 5 The device must be stored in a room without moisture The system maintains only person authorized by Sams elektronik doo Any voluntarily opening device upgrading or servicing is strictly prohibited and is subject to warranty void and the possibility of injury Places for fastening PROCEDURES FOR SAFE USE OF THE DEVICE 1 Remove the protective wrap from the chassis For dev...

Page 7: ...le for connection with remote control DC power supply PSU 1 Delivery includes device user manual INPUT Number 32 Signal type HD SDI to SMPTE 292M EQ Automatic to 100m with 1694A cable Impedance 75Ω Connectors BNC Specifications and designs are subject to change without notice HDV 3232 HD SD SDI routing switcher 32x32 HD SD SDI routing switcher 32x32 with monitoring output Master remote CP 3232 wit...

Page 8: ...ation of the presence of power supply RED LED overtemperature processor indication GREEN LED indication of the presence of remote control GREEN LED indication of communication in the local network YELLOW LED indication of the presence of Black Burst reference YELLOW LED indication of the presence of Tri Level Sync reference HDV 3232 front side Status is represented by LEDs on the front side POWER ...

Page 9: ... connect one source to multiple destinations except in the case of the DATA matrix which connects one source to a single destination To check that the source is connected to that destination simply press the desired source and destination buttons will illuminate If the destination is not illuminated that source is not used In the same way you can press a destination and check to which the source i...

Page 10: ...as a source until destination is unlocked Destination that is assigned to slave commands and which is locked can be unlocked with any remote controls in the system using the same destination as well as through the software on the PC UNDO Use this option if you want to restore the previous state of the connection Since this type of commands shutdown In a system where two or more commands can contro...

Page 11: ... the routing switcher powered on for the first time Remote control saves the previous state connections in the event of a power failure or deliberate shutdown In a system where two or more commands can control the same destination return to the previous state can be made with any such command PANEL LOCK Use this option when you want to lock the entire panel PC ENABLE LED flashes when the PC softwa...

Page 12: ...erically defined and should press single number from 1 to 16 the total number of additional commands Make sure that the selected address does not match with the already selected in another previously addressed slave commands Pressed button starts flashing In this way you will notice that selected address will be used for this command After selecting release PANEL LOCK key CONNECTORS Routing Switch...

Page 13: ...n the desired device and press the Web Browser located on the left side of the software Browser will display the configuration options NOTE The device will be found from across the network only if the device was connected to a network cable before turning on If the program NETFINDER does not find the device on the network try the following Connect the inserter directly to the computer The computer...

Page 14: ...when the ONLINE letters changed from large to small Once it stop the communication is interrupted REF Green 720p 1080p Red check cable or source references Yellow Pal NTSC Each number represents the buttons on the incoming signal Each row represents a destination and these are identified by name Pressing the button in one of rows connects selected input to a destination from that row After a few s...

Page 15: ...ETFINDER is not able to locate the device in the network try the following 1 Right click on Local Area Connection 2 Select option Change Windows Firewall settings 3 When a window Windows Firewall opens select tab Exceptions 4 Click on button Add program PROBLEMS AND SOLUTIONS IN A NETWORK ENVIRONMENT ...

Page 16: ...255 255 0 default gateway and DNS leave blank 5 Turn off all kinds of firewalls completely 6 Install Tiny DHCP server 7 In Tray icon will appear in the form of two shaking hands 8 Click on that icon 9 In the opened window click the button Add new 10 Enter the MAC address of the device MAC address is entered without dashes dots and spaces and press OK 11 If the field is not marked with the MAC addr...

Page 17: ...o output 1 input 2 to output 2 input 3 to output 3 input 4 to output 4 input 5 to output 5 input 6 to output 6 input 7 to output 7 input 8 to output 8 input 9 to output 9 input 10 to output 10 input 11 to output 11 input 12 to output 12 input 13 to output 13 input 14 to output 14 input 15 to output 15 input 16 to output 16 http 192 168 0 14 get_data dst00 0 dst01 1 dst02 2 dst03 3 dst04 4 dst05 5 ...

Page 18: ...CD into the CD ROM If the installation itself does not start open the contents of the disc and click the left mouse button twice on setup exe and follow up the instructions displayed during the installation 1 Introductory message advising that it is necessary turn off all open programs Press OK to continue the installation or EXIT SETUP 2 Press the button with the computer to continue the installa...

Page 19: ...nput DESTINATION NAME Name of output SOFTWARE At start there will be an indicator of communication with the master command If communication is realized at the intersection of XY axes are displayed connections as icons VIDEO AUDIO 1 AUDIO 1 AUDIO 2 red icon AUDIO 2 DATA green icon If the indicator of communication retain more than one minute 1 The communication parameters are not set 2 The main rem...

Page 20: ...ight corner of the main window there will be an indicator connected with green background Will not be displayed properly unless you do not connect or if the the master remote control is turned off Properties menu Choosing the serial port The connection is established NAMING OF SOURCES Each source can get their name based on the conditions of the matrix This feature is very useful for subsequent co...

Page 21: ...connection will be made only for those types of signals whose icon is active yellow For those who need to accurately see the section press the X on the keyboard picture below The intersection of horizontal and vertical lines will be bold red line Place the arrow at the intersection XY and press the left mouse button If you want to connect this connection press the OK button Otherwise press CANCEL ...

Page 22: ... button turns red Unlocks by pressing the button again LOCK PANEL You can lock the PC panel if you press the menu button LOCK PANEL Unlocking is done closing the window UNLOCK at center of the screen Panel is locked SAVE If you want to save your connection status press SAVE button Ctrl S This option is useful because in this way can be saved combinations of useful status of connections that will b...

Page 23: ...ES Each source can get their name based on the conditions of the matrix This feature is very useful for subsequent configuration of additional commands but to get a clearer insight into what actually connects Double click the left mouse button over the default names of the sources a window opens where you can rename the source After renaming press OK Type a new name in the field NAMING OF DESTINAT...

Page 24: ... 48x1 If the software is detected at this address it will display the command in the menu Panel Type which is then locked for a change If the software does not find the remote control at that address Panel Type menu is unlocked and can then be selected type of command ICONS LOAD FROM FILE Loading a previously configured panel that is recorded as a document on your computer SAVE TO FILE Saving conf...

Page 25: ...s not slave command so that it is selected CP 3232 32x32 for configuration and saving as a document on your computer DOWNLOAD BUTTON LAYOUT WITH CONTROLS LOAD FROM PANEL When opening the window for configuring the panel it shows the factory state of commands where the first source is the first key the second to second etc and also the destination By pressing LOAD FROM PANEL downloads arrangement o...

Page 26: ... down menu to select the source on the key The selected source is on the key CONFIGURING THE SLAVE COMMAND WITH DESTINATION SELECTION AND THEIR LAYOUT Choosing destinations is done as well as with the selection of sources and their arrangement In this case of commands there is only one destination Pressing the button opens the destination drop down menu to select picture below Click the left mouse...

Page 27: ...ys on slave commands it can be saved as a document on your computer This is very useful especially if you configure the commands that are not connected to the system and for later upload Also for commands that are in the system can be individually saved as a document or make various styles intended for the same configuration panel which will be used in the future Pressing the button SAVE TO FILE w...

Page 28: ...HDV Routing switchers elektronik Sams elektronik d o o sams sams rs www sams rs 28 NOTES ...