TECHNICAL SUPPORT AND SERVICE

Sams elektronik has made every effort to ensure that the equipment works in perfect condition. In 

the event that problems that occur can not be resolved, or if you have any questions regarding this 

equipment or information about other products produced from Sams elektronik, contact your local sales 

representative or call Sams elektronik directly through one of the ways listed below:

Sales: +381 11 3806 254

Technical support: +381 11 2402 212

Service: +381 11 4056 051

Email: 

Sales - [email protected]

Technical support and service - [email protected]

Web site: www.sams.rs

Address: 

SAMS ELEKTRONIK d.o.o.

48 Zivka Davidovica st

11050 Belgrade

Serbia

WARNING

TO AVOID ELECTRIC SHOCK, DO NOT OPEN COVER.

DEVICE MAINTENANCE REQUIRES PROFESSIONAL PERSON AUTHORIZED BY THE MANUFACTURER.
1.   Read all safety and operating instructions before using the device.

2.   Keep all safety and operating instructions.

3.   Follow the instructions from the user manual.

4.   Do not upgrade device, except in the case advised by the manufacturer.

5.   Do not use the device in the presence of water and / or moisture.

6.  Do not pour water or moisten the device with any type of liquid.

7.   Openings on device are provided for ventilation.

8.  Do not block air flow through the ventilation openings.

9.   This product is powered by AC ~ 230V ± 10%, 50Hz.

10.   This product is equipped with a three-wire cord with grounding.

11.  This device is equipped with a protective fuse in the power outlet. Do not bypass fuse.

12.  Do not replace the fuse. Replacement can be made by a person authorized by the manufacturer.

13.   Do not bend the power cord so that it can be damaged.

14.  Connect connectors as in the enclosed instructions. Deviations from the allowed values predicted 

for the inputs and outputs of the device can cause severe damage and warranty void.

15.  Do not use the device in an environment that contains flammable or explosive materials in any 

physical state.

16.   Turn off the power corde before cleaning. Do not use liquid, aerosol or flammable cleaners. Use 

only a dry cloth.

17.   Servicing  is  performed  by  a  qualified  person.  Removing  the  cover  user  is  exposed  to  high 

voltages.

18.   Never use the device when the cover is open and the device is powered on.

19.  Do not expose to extreme high or low temperatures.

20.  Do not expose to sudden temperature changes.

21.   Call service in the following cases:

 

- The power cord or plug is damaged

 

- Liquid or foreign objects is inside the device

 

- The machine is exposed to water and moisture

 

- The device does not function according to specification

 

- The unit has been dropped or damaged

 

- The characteristics are significantly changed 

22.   Use only specified replacement parts. 

23.   Professional person authorized by the manufacturer must check the device after completion of 

service.

24.   Allow a free rack unit (1RU) above and below the device for ventilation or put rack fan under the 

device.

Pictures and drawings listed in this user manual are for information purposes only and may differ 

from the actual device. Design and specifications of the device may change without prior notice.

Summary of Contents for AAD-2s

Page 1: ...16 april 2013 Updated 11 july 2014 Z10 3 edition 1 Code 005 302 005 303 ENGLISH Sams elektronik d o o 48 Zivka Davidovica st 11050 Belgrade Serbia Tel Fax 381 11 3806 253 381 11 2402 212 sams sams rs...

Page 2: ...er servicer has not completed repair or replacement within a reasonable time or if the manufacturer servicer did not perform repair or replacement without significant inconvenience to the consumer 5 T...

Page 3: ...with the device SAFETY WARNINGS FOR SRU RACK FRAME ELECTRICAL SHOCK HAZARD DO N OT O PEN CAUTION RIZIK OD S TRUJNOG UDARA NE O TVARATI DOK JE P OD N APONOM UPOZORENJE CLASS I DEVICE Grounding is conn...

Page 4: ...is equipped with a protective fuse in the power outlet Do not bypass fuse 12 Do not replace the fuse Replacement can be made by a person authorized by the manufacturer 13 Do not bend the power cord s...

Page 5: ...OVAL AND STORAGE 6 DESCRIPTION 7 MODULE INSTALATION IN SRU RACK FRAMES 9 BACK CONNECTORS 11 SRU REAR SIDE 12 PCB WITH THE LAYOUT OF ELEMENTS 13 OUTPUT IMPEDANCE SELECTION 13 FINE TUNE OF THE INPUT LEV...

Page 6: ...zed by Sams elektronik doo Any voluntarily opening device upgrading or servicing is strictly prohibited and is subject to warranty void and the possibility of injury Places for fastening PROCEDURES FO...

Page 7: ...ctor 001 605 SRU 306 Rack frame for 6 modules BACK CONNECTOR BCAA 61 Specifications and designs are subject to change without notice AAD 2 2ch analog to 1ch AES EBU converter Broadcast quality 24bit c...

Page 8: ...ance 40K balanced S N ratio 80dB Max level 24dB REFERENCE INPUT Analog BB 300 mV DARS Word clock optional 1 BNC female AES3 110 or 75 OUTPUT Connectors 1 XLR Impedance 110 or 75 Nominal level 3 1 Vp p...

Page 9: ...RACK FRAMES Make sure that the module is set to the correct place in relation to the back connector BEFORE INSTALLING OR REMOVING THE MODULE FROM SRU ALWAYS TURN OFF THE POWER Lock module with lever...

Page 10: ...lektronik d o o sams sams rs www sams rs 10 Converters 1 2 3 1 The module set between the guides not metal plate 2 Locking lever mount behind the groove 3 Push the lever to lock in an upright position...

Page 11: ...2 ANALOG AUDIO IN 1 G G AAD 2 G G AES OUT 1 ANALOG AUDIO IN 2 ANALOG AUDIO IN 1 REF G G AAD 2 SPDIF OUT 1 ANALOG AUDIO IN 2 ANALOG AUDIO IN 1 REF G G G AAD 2 IN 2 IN 2 AAD 2 G G AES OUT 1 ANALOG AUDIO...

Page 12: ...ctor with M2 5 screw 1 Mass 2 Power switch 3 The socket 4 Connections for back connectors Rear side view SRU REAR SIDE DO NOT INSERT SHARP METAL OBJECTS OR FINGERS INTO THE SPACE BEHIND THE POWER PANE...

Page 13: ...e selection 110 or 75 OUTPUT IMPEDANCE SELECTION FINE TUNE OF THE INPUT LEVEL Set the jumpers to set the output impedance For fine tune of the input level use trimmers JMP2 OUTPUT 1 CH 1 HP 1 CH 2 HP...

Page 14: ...r AAD 2s www sams rs POWER DARS LOCKED BB LOCKED WC LOCKED FREE RUN OVERFLOW CH1 OVERFLOW CH2 Connect the power cord The device works only on AC 230 V 50 Hz Rear side Connect all necessary connectors...

Page 15: ...a pode avanju Prednja strana Ulaz eksterne rererence Ure aj podr ava DARS BB WC Analogni audio ulazi Digitalni audio izlaz 1 2 3 4 5 6 ON OFF 1 2 3 4 5 6 ON OFF 1 2 3 4 5 6 ON OFF 1 2 3 4 5 6 ON OFF 1...

Page 16: ...AAD elektronik Sams elektronik d o o sams sams rs www sams rs 16 Converters NOTES...

Reviews: