3.1. DESCRIPTION
SEC-1212P / SEC-1223P / SEC-1235P / SEC-1223P-M are Switched Mode Power Supplies (SMPS)
which convert 100-240 VAC, 50/60 Hz to regulated 13.8 VDC.
Features
• Complies with Minimum Energy Performance Standard (MEPS) for External Power
Supplies and meets Directives issued by: CEC (USA)/ DoE (USA) / NRCan (Canada)/ GEMS
- MEPS (Australia and New Zealand) / ErP Directive (European Union) / International
Efficiency Marking Protocol
• Efficiency Levels: (i) Level VI at input voltage of 115VAC (ii) Level VI at input voltage
of 230 VAC
• Universal AC input range of nominal 100 VAC to 240 VAC, 50 to 60 Hz allows interna-
tional application without changing jumpers / switch positions
• Power Factor (PF) corrected to > 0.9 at loads > 50% allows lower input current and line
losses, lesser harmonic distortion and lower RF noise
• Uses highly integrated Switched Mode Controller combining PWM Control & Active
Power Factor Correction for lower component count, higher efficiency and reliability
3.2.
CONNECTION & OPERATION
WARNING!
Before plugging the unit to the AC outlet, please check that your local supply
voltage is 100-240 VAC, 50/60 Hz.
NOTE! The DC output connectors (3 and 4, Figs 2.1 to 2.3) have a tubular hole
of diameter 0.2” (5mm) with a set screw. For a firm connection, crimp/solder
pin type copper terminal on the cable ends of your 12V DC device (2 Pin Type
of terminals (for wire size up to AWG #8) have been supplied with the unit].
MISE EN GARDE!
Avant de brancher l’unité à la prise secteur, veuillez vérifier que votre tension
d’alimentation est de 100-240 VCA, 50/60 Hz.
REMARQUE ! Les connecteurs de sortie (DC 3 et 4, figures 2.1 à 2.3) a un di-
amètre de trou tubulaire 0,2” (5mm) avec une vis. Pour un lien ferme, à sertir/
soudez les broches de cuivre de type borne sur les extrémités du câble de votre
appareil DC 12V (2 broches type de terminaux ont été fournis avec l’appareil).
Ensure that the power supply’s ON/OFF switch (1, Fig 2.1 to 2.3) is off and the power supply
is unplugged from the AC outlet. Switch off your 12 V DC device and connect it’s Positive
and Negative to the RED (Positive) and BLACK (Negative) terminals respectively (3 and 4, Figs
2.1 to 2.3). Ensure that the connections are secure and tight. Plug the power supply into the