16 | SAMLEX AMERICA INC.
SECTION 6
| Specifications
NOTE: Specifications are subject to change without notice.
6.1 SEC-1212P
Input: 115 VAC
Input: 230V
INPUT
Input Voltage Range
100-240 VAC
Input Frequency Range
50-60Hz (47-63Hz)
AC Input Current
1.48A at 120 VAC
0.72A at 240 VAC
1.54A at 115 VAC
0.75A at 230 VAC
1.80A at 100 VAC
0.90A at 200 VAC
Inrush current on switching ON
30A (Cold start)
60A (Cold start)
Power Factor at full load
> 0.9
No Load Power Draw
< 0.21W
<0.5W
Average Efficiency
> 89%
>91%
Energy Efficiency Level
Level VI at 115 VAC input
Level VI at 230 VAC input
PWM Switching Frequency
75 to 150 KHz
PFC Switching Frequency
25 to 68 KHz
OUTPUT
Output Voltage
13.8V ± 0.1V
Output
Current
Rated
11A
Current Limit
13.2 to 14.2A
13.7A
Output Power
151.8W
Output Ripple and Noise
100 mV peak to peak at full load
Output Voltage Adjustment Range
12.5 to 15.0 VDC
Output Voltage Tolerance at no load
± 0.1V
PROTECTIONS
Overload and Short Circuit
Hiccup Mode at 120% (13.2A). Auto reset when fault is removed.
Output Over Voltage Protection
By PWM Controller (16.5 ± 0.5 VDC)
Cooling
By convection. No fan
Over Temperature Protection
The unit will shut down when the temperature of the
Primary Heat Sink rises to 105°C ± 5°C. Auto reset
when the temperature drops to 75°C ± 5°C
Internal AC Side Fuse
250V, 2.5A; Time Delay Type; 5mm x 20mm
ENVIRONMENTAL
Operating Temperature
-20°C to +50°C: 100% rated power
Over Temperature Protection
50°C – 60°C: Linearly de-rate from 100% power
at 50°C to 80% power at 60°C
COMPLIANCE - SAFETY
UL Safety Listed
USA
UL 62368-1, 2014-12-1
Canada
CSA C22.2 No. 62368-1-14, 2014-12
Summary of Contents for SEC-1212P