![Samoa LARIUS VEGA 34:1 Operating And Maintenance Manual Download Page 60](http://html1.mh-extra.com/html/samoa/larius-vega-34-1/larius-vega-34-1_operating-and-maintenance-manual_3876553060.webp)
REV.
07 - 01/2022 - Cod. 150089
www.larius.com
60
VEGA 34:1
Fig. 10O
Fig. 11O
Fig. 12O
O10
O10
O14
O13
O15
A
3,5 mm
IT
EN
•
Check the condition of each piece, in particular of the gaskets (
O10
) and the O-ring (
O13
), (
O14
) and (
O15
).
Control that the inner walls of the cylinder are not scratched. Before reassembling all parts, lubricate them with light and
water proof grease.
•
Adjust then the distance (
A
) between the gaskets and the surface of the piston. This adjustment shall be done with the cross
piece (
O6
) down and it can be better done by using our special metering device.
After having reassembled all parts, before connecting the group to the pump, test it by feeding a small quantity of air (3-4
bar).
•
For a correct reassembly, refer to the pumping group detailed drawing, by following the disassembly instructions in reverse
order.