GROUNDING
J
The optimal condition to achieve perfect coating and complete
safety for the personnel is the proper grounding of all system
components. In particular, make sure that:
• All system components are duly grounded.
• The hook holding the piece to be coated is perfectly clean.
• Tubes and grounding cables are not damaged. Should they
be worn, provide for their replacement.
An improper grounding may produce thick mists
of paint that may represent a risk of intoxication
for the personnel and an inadequate coating
(
pattern will not shape, deformed pattern, wrap
back effect, etc..
).
To avoid these inconveniences, make sure that
all system components are properly grounded.
Never use non-conductive tools and/or tanks
made of plastic or wood.
J.c - GROUNDING OF OPERATOR’S GLOVE
• Personnel operating the gun should not wear shoes with
rubber or plastic soles. If protection gloves are used,
provide a suitable grounding (
J4
) of the gloves (
J5
).
Product
Product
J1
J1
J2
J3
J5
J4
J.b - GROUNDING OF THE FLUID
•
Provide a suitable grounding (
J1
) for the pump (
L2
) and the
fluid tank (
J3
).
J.a - GROUNDING OF THE GENERATOR