www.larius.com
10
Omega 23:1-30:1
ED.
04 - 09/2021 - Cod. 150150
F2
F1
*
The
OMEGA
pump is generally supplied on support for wall
fastening or on trolley or on double post ram.
For the correct fastening of the pump on other structures use
the 4 holes placed at the base of the pneumatic motor (see the
illustration for dimensions).
Fig. 2H
L
I
Fig. 3I
*Int. holes
In condizioni climatiche rigide è necessario inserire del liquido
antigelo (
F1
) all'interno del gruppo FRL (
F2
)
If 100% pure antifreeze liquid is used, it is recommended the
dilution shown in the table.
DILUITION RECOMMENDED FOR PURE PRODUCT
% water diluition
°C, environmental temperature
10%
-5
20%
-10
30%
-20
40%
-25
50%
-37
60%
-50
NOTE
When the pump is used in places with higher
temperatures, the phenomenon indicated
above may not occur and therefore it is not
necessary to use antifreeze.
SETTING UP
TYPICAL INSTALLATION
CONNECTION TO THE FEED AIR
•
For pump feed use a hose with an internal diameter no
lower than 20 mm.
Install at the pump inlet an air pressure regulator
(it is suggested complete with condensate filter
and lubricator). The outlet pressure of the material
is 23 times (OMEGA 23:1) or 30 times (omega 30:1)
the inlet pressure of the pump feed air. Therefore,
it is extremely important to adjust the value of the
feed air pressure.
COLLEGAMENTO DEL TUBO USCITA MATERIALE
•
Connect the high pressure hose at the outlet of the pump.
It is recommended to tighten the fittings.
PUMP FASTENING ON THE HOIST
•
For the correct fastening of the pump on the ram, follow the
procedure described in the manual for use and maintenance
of the double post ram.