SmartVide
X
|
Operation
6
User’s manual — 2901344/0
System information
This screen displays information about the use of the machine.
/left]
Language
This screen is used to select the user interface language (Spanish,
English, French, German, Italian, Portuguese).
Date, Time
Set the date and time for the machine.
Temperature unit
Select the temperature unit: degrees
Celsius
(°C) or degrees
Fahrenheit
(°F).
Check/Edit tag
View and edit the
tag
number. [
/right]. There are two types of
tag
:
•
Factory numbered (digitally and physically)
tags
. The
tag
num
-
ber cannot be edited. It is just for checking the number.
•
Non-factory numbered
tags
. Used to (digitally and physically)
check and edit the
tag
numbers.
See also: [
Controlled regeneration mode with tags
Edit regeneration recipes
Access and edit the name and time of the regeneration recipes.
/right]
Fig. 5:
Screens
Calibration of Probes
and
Edit regeneration recipes
Wi-Fi
Access and select the
Wi-Fi
network.
Audio
Turn machine audio on and off
Machine name
Access and edit the machine’s name. The machine’s name appears
on the main menu screen under the navigation bar [
/A].
Calibration of probes
Calibrates the machine’s temperature sensors. [
/left]
Restore factory settings
Restore the initial factory settings.
3.6
Sous-vide
manual mode
3.6.1
Cooking with water temperature or sensor
temperature
The
SmartVide X
manual cooking mode is a versatile cooking
system with the following operating modes:
Fig. 6:
Cooking with water temperature (left: with time; right: without time and sen
-
sor in read mode)
•
Cooking based on the water temperature
–
SET temperature and time
: When the water reaches the SET temper
-
ature, the SET time starts counting down. [
/left] shows that
6
hours and 25
minutes remain to finish the cycle from the initial
SET time of 12
hours and 30
minutes.
–
SET temperature without time
(continuous time mode): Once the
cycle has been started, the screen shows the time elapsed since the
start. [
/right] shows that 1
minute has elapsed since the cycle
was started.
–
Needle probe connected in read-only mode:
If you add the needle
probe during the cycle, the temperature values will be in read-only
mode and will not influence the cycle. [
/right]
Fig. 7:
Cooking with temperature probe (left: with time; right: without time)
•
Cooking with needle probe temperature reference
–
SET needle probe temperature and time
: During the cycle, the time
starts counting down when the needle probe temperature reaches its
SET value. [
/left]
–
SET needle probe temperature without time
: Upon starting the cycle,
the time starts counting until the temperature reaches its SET value.
/right]
Notice
Risk of data loss
When restoring the factory settings, the machine resets the fol
-
lowing data fields:
– List of recipes. [
/2]
– List of users. [
/4]
– Log. [
/3]
– Regeneration recipes. [