BLAST CHILLER ISTRUCTION
05/2014
Evaporator cleaning
•
The interior of the evaporator must be cleaned periodically
in the following manner:
•
Remove the screws that hold the steel fan panel from the
evaporator and open the panel as indicated
•
Clean the evaporator battery using a jet of hot water at low
pressure, aiming it from high to low on the evaporator. Make
sure that the water is drained through the drain pipe.
•
When complete, used compressed air to remove all of the
water from the evaporator battery.
•
Repeat the operation described above to close the fan panel.
Before starting the machine, make sure you have remo-
ved any tools used for cleaning and that the drain plug is
closed.
7.5 DEFROST WATER DRAINING
•
the system is set up for automatic (in certain models)
and manual defrosting when necessary.
•
make sure that the evaporator water is correctly draining in
the collection basin, avoiding any obstructions of the drain
pipe.
Fig. 1
Fig . 2
Fig . 3
Fig . 4