Index revision : A
40
7116
6.3.9.1. Preparation of the high voltage connection
WARNING : Ensure not to damage the insulating
jacket. The smallest nick or mark on the
insulating jacket will cause the cable breakdown.
•
Step 1
: Strip using a tool type strip-cable (rice
grain) the high voltage cable over 33.5 cm
length for the violet sheath then strip the semi-
conductor sheath (black sheath) by peeling it
and cut it using pliers on the same length. It is
imperative not to use a standard tool slicing
”cutter”.
•
Step 2
: Insert the seal the grip in the nut
•
Step 3
: Thread the nut equipped, split cone and
sleeve must be kept against the cable.
DES06461
Ground Plug
HV cable
Holder
nut
Split
cone
Sleeve
Terminal
end
Grip
Banana plug
Resistance
Step 1
Step 2
Step 3