5.3. Shutdown and startup procedures
Important recommendations:
Comply with the air settings given in Section 3.2.
The bearing air pressure must be at least 5.5 bar at the quick-disconnect plate.
Check that the speed regulating module transmits a signal.
5.3.1. Shutdown procedure
Important steps be observed:
WARNING : * Wait until the turbine has stopped completely stop: 0 rpm.
5.3.2. Start-up Procedure
Important steps to be observed:
Seq
u
enc
e
cha
rt
Step 1
Step 2
Step 3
Step 4
Step 5
Stop atomising.
Switch off the high-voltage
power supply
Run a rinsing cycle
Cut off the shaping air
Cut off the turbine rotation
air (*)
Cut off the bearing air
Se
que
nce
c
h
art
Step 1
Step 2
Step 3
Step 4
Switch on the bearing air
supply
Start up turbine rotation
Switch on the shaping air
supply
Switch on the high voltage
supply
Start up atomisation