7116
6.3. Corrective maintenance
The following operations are preferably performed in a workshop.
6.3.1. Procedure D1: Body installation/removal
•
Remove the
body
: Unscrew the PPH nut then pull the body assembly along the axis.
•
Reinstall the
body
: Proceed in reverse order.
6.3.2. Procedure D2: Replacement of body o-rings
• Check the condition of the o-rings on both faces
of the body and replace if necessary.
O-ring kit (turbine side) P/N 910003415.
O-ring kit (quick-disconnect plate side) P/N
910003416.
WARNING : Prior to reinstalling the body on the
rear support, make sure all the o-rings are pres-
ents.
6.3.3. Procedure D3: Replacement of solvent pipette
•
Remove the solvent pipette:
This operation automatically destroys the sol-
vent pipette.
If absolutely necessary, remove the solvent
pipette using an M1.6x 0.35 screw.
Replace the solvent pipette and install it in the
body.
Body turbine
side
Body quick-dis-
connect plate side
Solvent pipette