30
7116
6.2.2. Procedure B1: Magnetic bell cup
WARNING : All bell cup maintenance or handling operations must be performed with extreme
care, since the bell cup is balanced.
WARNING : Stop the turbine and cut off the shaping air. The bearing air remains pressurized.
• Remove the magnetic bell cup using the tool (P/N # 900000803).
• Carry out a visual inspection.
• Let the bell cup soak for one hour in an appropriate rinsing liquid, then clean with a clean cloth and
soft brush.
WARNING : Make sure that all surfaces are clean and completely free of impurities, particularly
the inner and outer surfaces of the bell cup fastening cylinder.
• Dry carefully with compressed air.
• Reinstall the bell cup on the atomizer.
DES02807
DES02808
Solvent