Index revision : A
17
7140
4.2.2.
Installation of the
Inorecip H
(option)
Inorecip H
must be installed on a flat floor with a
resistance of 40 daN/cm
2
.
WARNING :
it is imperative to respect the mini-
mum distance of 350 mm between the Inorecip
V and the inside of the powder booth.
WARNING : The handling of the Inorecip V must
be done by at least two operators and the lifting
equipment must be adapted to the weight and
size of the robot.
Remove the two protective covers of the
Inorecip H
with 4 M4 screws per cover.
Remove the 2 side covers of
Inorecip V
with 6 M4
screws per cover.
Remove the 4 wheels of the
Inorecip V
by remo-
ving the 4 M8 screws per wheel.
DES07924
1000
350 mini
Inorecip H
Out of ex-
plosive at-
mosphere
Zone 22
Inorecip V
DES07918
Protective covers
DES07919
Side covers
DES07920
4 M8 screws
Wheel