SAMES KREMLIN
Page 6
Manual : 573.190.112
INSTALLATION
HA
HB
B
MP
S
A
AC
19
17
18
13
14
11
12
9
8
15
20
Interconnect hoses (18) and (17) between the pump and the gun :
The hose (18) should be static proof (green band, ID 7mm / 9/32" or 8 mm / 5/16" for a gun,
model HTi)
The hose (17) should be a fluid hose (ID 7 mm / 9/32").
Connect the pump air supply to the compressed air network by means of an hose (ID 10 mm / 3/8 ").
Nota : these hoses are not included in the equipment.
The PU 2125F pump is fitted with an earth cable. Ground the pump.
Fill with T lubricant or with an appropriate lubricant the BASE fluid section flange. Fill the cup to the 3/4.
Unscrew the 2 air regulators (8 & 9), then supply the equipment with air (maximum P = 6 bar / 87 psi,
clean air).
→
Do not install isolating valve on the CATA supply system
(between the tank and the
FLOWMAX
fluid section).
It will damage the bellows.
→
Do not install a system that will act as a non return valve.
→
You
must not
create an
overpressure
in the CATA system.
5. OPERATING
LABEL
The label sticked on the pump explains the 3 operating stages of the pump : PRIMING - WORKING -
FLUSHING.
The 3 operating stages are selected :
- working the manifold valve (11) (
→
index A on the label),
- operating one of the valves of the color changer (12) (
→
index B on the label),
- working the valve (20) located at the base and solvent suction (
→
index S on the label).