SAMES KREMLIN
Page 11
Manual : 573.190.112
10.TROUBLESHOOTINGS
HA
HB
B
MP
S
A
AC
19
17
18
13
14
11
12
9
8
15
20
THE PUMP DOES NOT OPERATE
Check:
♦
It is supplied with air,
♦
The valves (11 & 12) are in 'WORK' position,
♦
The gauge (9) indicates a pressure between 2
and 6 bar / 29 to 87 psi,
♦
The mixer (15) and the hose (17) are not clogged,
♦
The gun filter, if there is one, is not clogged,
♦
The gun nozzle is not clogged.
RATIO CHECKING
From time to time, you must check the ratio :
1 - The CATALYST container is translucent. Mark on the CATALYST level, then add a CATALYST
volume (for example 1 liter / 0.26 US gal),
2 - Determine the volume of the BASE,
3 - Operate the pump until the volume of catalyst falls to its initial level,
4 - Determine the volume of BASE used. In this case, the ratio is :
Volume of BASE used (in liters) = Material mix ratio
*
1 liter
*
Nota : The reading of the proportioning ratio is highly sensitive to the viscosity of the materials.