Use of equipment
582108110-EN-indG-Pompe Azur-52C225.docx
62
12.4
Diagnostic help / Troubleshooting guide
Troubleshooting
Before any intervention on a pump, it is imperative to carry out a
general procedure of decompression and purge.
In order to avoid the risk of personal injury, product injections, injuries
caused by moving parts or arcing, it is essential to follow the following
procedure before any intervention during system shutdown, assembly,
cleaning or changing the nozzle.
Lock the guns (valve, tap, etc.) to OFF.
Shut off the air supply through the decompression valve
in order to evacuate the residual air from the motor.
Unlock the gun (valve, tap ...).
Bring the gun (valve, tap ...) to a metal bucket to collect
the product. Hold it against the wall of this bucket to
avoid interrupting the continuity of the earthing (use the
wire with stirrup to put the metal bucket to earth).
Open the gun (valve, tap) to bleed the circuit.
Lock the gun (valve, tap) to OFF.
Open the pump bleed valve and collect the product in
a well-grounded metal bucket.
Leave this purge valve open during the whole period of
the operation.
Check the conformity of the wiring before intervention.
Summary of Contents for 64350225130000
Page 41: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docxx 41 8 Equipment plans Pump 52C225...
Page 42: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docx 42 Wall mounted pump...
Page 43: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docxx 43 Pump 52C225 Cart...
Page 44: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docx 44 Pump 52C225 Cart Hopper...
Page 45: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docxx 45 Fluid section C225...
Page 46: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docx 46 Motor 7000 Stroke 120...
Page 47: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docxx 47 Air supply...
Page 48: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docx 48 Filter...
Page 49: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docxx 49 Pump priming kit...
Page 50: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docx 50 Hopper...
Page 167: ...Pneumatic Wiring 582108110 EN indG Pompe Azur 52C225 docx 167 Indirect air control...
Page 214: ...Spare parts 582108110 EN indG Pompe Azur 52C225 docx 214...
Page 215: ...Spare parts 582108110 EN indG Pompe Azur 52C225 docx 215...