Operation
26/05/2020
582115110-EN-indC-Pump-01D140-01D140E.docx
40
8.2
Troubleshooting
Rectification of malfunctions
Malfunction
Cause
Rectification
Pump not running or running
too slowly
Compressed air pressure too
low
Set the pressure from 4 to 8
bar / 39.2 to 116 psi.
Hose cross-section too small Use hose with a larger cross-
section
Control valve leaks
Replace spool valve and
seals
Blockage on the sound
absorber, pump running
laboured, seal swollen or
piston material damaged
Check material resistance,
prevent running dry
Pump runs but does not
convey medium or does not
stop when the pressure side is
isolated
Valves contaminated
Flush pump with a cleaning
agent
Conveying hose blocked
Clean conveying hose
Suction and pressure valves
contaminated
Allow the pump to run at
maximum speed for approx.
10 to 20 minutes
Leaking connections, possibly
sucking in extraneous air,
vacuum breaks.
Check connections for leaks,
re-seal
Valves contaminated
Clean or replace valves
No suction effect on the
suction and discharge side
Close the openings by hand
and check the suction effect,
replace seals as required
Viscosity of the conveyed
medium too high
High-viscosity media are not
conveyable (for limit value
see chapter "Technical
characteristics")
Conveying hose split or
exhibits pin-sized holes
Replace conveying hose
Summary of Contents for 01D140
Page 23: ...Identification 582115110 EN indC Pump 01D140 01D140E docx 26 05 2020 23 Pump model 01D140E...
Page 29: ...General specifications 582115110 EN indC Pump 01D140 01D140E docx 26 05 2020 29 Dimensions...
Page 55: ...Spare parts 582115110 EN indC Pump 01D140 01D140E docx 55 12 Spare parts 12 1 Exploded view...