Doc.-ID: 160720-PT08BA-SS-ExCam IPP5635_en_rev.00.docx, page 5 of 24
2
Technical Data
2.1
Parameters of the explosion protection
Identification marks according to
directive
2014/34/EU:
II 2G (Zone 1 and 2)
II 2D (Zone 21 and 22)
Explosion protection (gas):
Ex d IIB T6 Gb or
Ex d IIB T5 Gb
Explosion protection (dust):
Ex tb IIIC T80°C Db IP68 or
Ex tb IIIC T95°C Db IP68 or
Protection level:
IP 66/68 (IEC /EN 60529)
Transportation and storage
temperature (EX):
-4
0°C…+60°C
Ambient temperature (EX)
1
:
-5
0°C…+50°C (T6)
Noticed body:
TÜV Rheinland (number 0035)
EU Type Examination:
TÜV 14 ATEX 7539 X
IECEx TUR 14.0026X
Test protocol ATEX:
557/Ex.539.00/14
Test report IECEx:
DE/TUR/ExTR14.0026/00
Quality Assessment Report:
DE/BVS/QAR14.0006/00
2.2
Electrical parameters of the camera
Axis P5635-E
Power supply:
PoE, IEEE 802.3at Class 4
Reference power:
48 V DC (44...54 V DC)
Maximum power input:
20 W
1
Maximum ambient temperature range relevant for explosion protection might deviate to the maximum functional temperature range.