5.3.2
Opening the pressure-resistant housing
The opening of the TNXCD housing requires special tools and it is not intended that cus-
tomer open the housing. In case that due to an unforeseeable event the housing has to
be opened, inform SAMCON Support (
) prior to executing any
measures.
Always observe all ex-relevant restrictions:
„WARNING – DO NOT OPEN IN HAZARDOUS AREA“
Note: Depending on the zone classification, it might be necessary to
obtain a work permit/clearance! Even after disconnection of the volt-
age, it is mandatory to avoid potentially explosive atmosphere when
opening the camera housing (de-installation of the camera and execu-
tion of the work within the safe area (non EX)!
Attention!
Beware not to damage the surface of bore hole and shaft (fit) at the
flame proof gap preventing the transmission of ignition.
Attention!
Please make sure not to damage housing sealings and to keep them
clean