background image

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Ex

Cam

 IPP5635 

 
 

User manual 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for ExCam IPP5635

Page 1: ...ExCam IPP5635 User manual...

Page 2: ...4 Illustration of the model key 8 5 Commissioning 10 5 1 Step 1 Installation 10 5 2 Step 2 Electrical connection 10 5 2 1 Potential equalization 11 5 2 2 Connection and protection 12 5 2 3 Tests prio...

Page 3: ...13 Figure 5 5 ExCam IPP5635 T08 TNXCD B XXX P L L 13 Table 5 2 Pin assignment SKDxx and plug contact RJ45 15 Figure 5 6 RJ45 Contact assignment 15 Figure 5 7 SKDxx Pin assignment 15 Table 5 3 Pin assi...

Page 4: ...the high speed and precession with which the pan as well as the tilt functions is carried out The ExCam Series is certified according the European ATEX directive as well as to the international IECEx...

Page 5: ...temperature EX 40 C 60 C Ambient temperature EX 1 50 C 50 C T6 Noticed body T V Rheinland number 0035 EU Type Examination T V 14 ATEX 7539 X IECEx TUR 14 0026X Test protocol ATEX 557 Ex 539 00 14 Tes...

Page 6: ...aracteristics PUR halogen free flame retardant UV resistant chemical resistance shielded Interface P version RJ 45 EIA TIA 568B 10BASE T 100BASE TX PoE K version 8x single pin twisted pair solid condu...

Page 7: ...l EN 60529 IEC 529 IP 68 Test conditions 24 h 3 m water column at 5 C An additional mechanical protection against water jets is recommended Housing material Stainless steel MNo 1 4404 X2CrNiMo17 12 2...

Page 8: ...D B 005 P N ExCam IPP5635 T08 TNXCD B 005 K L T08 TNXCD B 005 P L ExCam IPP5635 T08 TNXCD B 005 K LL T08 TNXCD B 005 P LL Table 4 1 Model key 1 ExCam IPP5635 Functional camera description of the ExCam...

Page 9: ...440p2 x 2 5 mm2 Cu litz wire with ferule sheath about 10 cm stripped and furnished with bend relief shrink tubing P Plug termination optional SKDxx RJ 45 network plug heavy duty AWG 26 22 Pin assignm...

Page 10: ...essories as well as safety guidelines are described in the EX installation manual of the ExCam se ries 5 2 Step 2 Electrical connection Attention The electrical connection of the equipment must be exe...

Page 11: ...mera s flameproof enclosure done by the user is prohibited Depending on the model option the ending of the camera s cable connection is either stripped to the blank Cu conductors or furnished with a p...

Page 12: ...Doc ID 160720 PT08BA SS ExCam IPP5635_en_rev 00 docx page 12 of 24 5 2 2 Connection and protection Figure 5 2 ExCam IPP5635 T08 TNXCD B XXX K N Figure 5 3 ExCam IPP5635 T08 TNXCD B XXX P N...

Page 13: ...Doc ID 160720 PT08BA SS ExCam IPP5635_en_rev 00 docx page 13 of 24 Figure 5 4 ExCam IPP5635 T08 TNXCD B XXX K L L Figure 5 5 ExCam IPP5635 T08 TNXCD B XXX P L L...

Page 14: ...v table 5 2 Generally the pins of the same color code are connected Only use SAMCON ap proved clamps It is allowed to separate the ExCam IPP5635 from the network and to switch it on again while in ope...

Page 15: ...of the power supply is not necessary The power supply is executed by the PoE network device via an electronic with intelligent set up The camera as well as the con nection is permanently monitored in...

Page 16: ...use L 6000 mA T time lag high inrush current 60 W fuse L 6000 mA T time lag high inrush current L 2 BK 2 5 mm2 litz wire 0 VDC GND Table 5 3 Pin assignment supply cable 5 2 3 Tests prior to switching...

Page 17: ...ion it might be necessary to obtain a work permit clearance When adjusting the camera settings potentially explosive atmosphere must be avoided by any means To allow the camera delivering the best pic...

Page 18: ...relevant restrictions WARNING DO NOT OPEN IN HAZARDOUS AREA Note Depending on the zone classification it might be necessary to obtain a work permit clearance Even after disconnection of the volt age...

Page 19: ...case the applicable settings have to be carried out within the menu System Options Ad vanced Plain Config User root Password root 6 1 Browser Support A list with the currently supported web browsers...

Page 20: ...installed within the same network segment physical subnet as the computer on which the AXIS IP Utility tool is executed For example the ExCam IPP5635 network identification is Axis P5635 E q v figure...

Page 21: ...intenance measures are necessary they have to be initiated and or executed 8 Repairs and Maintenance Repairs must only be carried out with original parts of SAMCON Prozessleittechnik GmbH Damaged pres...

Page 22: ...D models All drawings 3D models certificate and more is available in the download area of the product page on our homepage http www samcon eu en products network excam IPP5635 In case of missing techn...

Page 23: ...Doc ID 160720 PT08BA SS ExCam IPP5635_en_rev 00 docx page 23 of 24 11 Notes...

Page 24: ...Doc ID 160720 PT08BA SS ExCam IPP5635_en_rev 00 docx page 24 of 24 Schillerstrasse 17 35102 Lohra Altenvers www samcon eu info samcon eu fon 49 6426 9231 0 fax 31...

Reviews: