14
•
SPS-300 Series Program Information
SPS-300 SmartECR Supplement v1.11
SPS-345 Memory All Clear
1.
Turn the power switch located on the right side of the register to the
OFF
position.
2.
Turn the control lock to the
S
position.
3.
Press and hold the key position where the
CHECK
key is located on the default keyboard layout:
SPS-345
Press and hold the
SUBTOTAL
key position
during power-up in
S
4.
Continue to hold the
SUBTOTAL
key while turning the power switch to the
ON
position. The
message “RAM ALL CLEAR" displays.
5.
Press the upper left key of the keyboard, then the lower left key, then the upper right key, and
finally press the lower right key.
3
1
4
SPS-345
Expanded
(63 PLU keys)
2
3
1
4
2
SPS-345
Default
Configuration
(21 PLU Keys)
Note:
In the default configuration, there are 21 double-width PLU keys. Under each key, the left-most
key is inactive and the right-most key is active. The four-key sequence shown with the default
configuration will set the keyboard in the default 21-PLU key configuration.
When the keyboard is expanded, the four-key sequence shown will set the keyboard in the expanded
configuration.
If you wish to build a custom configuration, you will want to perform a memory clear for the expanded
configuration, and then assign each key position individually.
6.
After a short delay, the printer will display the message: "Please Wait …. ". Memory is cleared,
the default program is installed and the RAM CLEAR receipt is printed. The display now reads:
2-STATION PRINTER : ‘CASH’ Key
1-STATION PRINTER : ‘CLEAR’ Key
7.
Press
CASH
(the Er-945 has two printers)
8.
The display now reads: