Installation - Replacing product
Deleting Wiring Centre from the network.
Press for 15
seconds to delete
the wiring centre
from the network.
All LED’s will flash
momentarily and
then the wiring centre will
be deleted from the
network. All thermostats
relating to the wiring centre
will need to be reconfigured
and paired with the new
wiring centre.
If the wiring centre cannot be deleted
as above, use the method below.
Please follow step 1
on page 47. Select
password 46.
You are now
ready to
install your
new wiring
centre.
Before replacing any device it must be removed from the Zigbee network.
Please ensure the Zigbee coordinator is also in pairing mode.
VS20WRF and VS20BRF Installer Manual
55
INST
ALLA
TION
iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:38 Stron