TESTING/PAIRING

Setpoint temperature

Operations

Initial Power UP

After power up, the thermostat is reset. During system reset, all LCD icons are displayed for 2 seconds and 
the keys are locked. After that, all keys are unlocked and the thermostat is initialized. Then software version is 
shown. The typical reset display is shown below. 

The following table shows the settings of the RT310 digital thermostat after RESET button is pressed:

Function

Status after Reset

Operation Mode

Normal mode

Room Temperature

22.0°C, to be renewed within 5 seconds

Setpoint Temperature

20.0°C

°C indicator

On

Frost Protection indicator

Off

Heat indicator

Off

Low-Battery Warning indicator Off, to be renewed within 5 seconds
Output Relay

Off

Reviewing Setpoint Temperature

Press        or         to review Setpoint temperature. The flame icon won’t be turned on.

When operating in Frost protection mode, the LCD will show frost setpoint with the Frost Protection 
indicator displayed.

Press Backlight or wait 2 seconds without keys pressed to return to normal operation, room temperature will 
be displayed.

TESTING/PAIRING

Actual room temperature

RT310 Installation Manual      09

Summary of Contents for RT310

Page 1: ...Installation Manual Model RT310...

Page 2: ...nformation 3 Box Content 3 Introduction 4 Features 5 Installation 5 Button functions and keys 7 Installer Mode 8 Operations 9 Other functions 11 Factory reset 12 Technical info 12 Warranty 13 02 RT310...

Page 3: ...ance with the EU and national regulations For indoor use only Keep your device completely dry ThisproductmustbeinstalledbyacompetentpersonandinaccordancewithalltheEUandnationalregulations Always isola...

Page 4: ...do its job The best way to do this is to set the room thermostat to a low temperature say 18 C and then turn it up by one degree each day until you are comfortable with the temperature You won t have...

Page 5: ...e thermostat on an outside wall above a radiator or in a location where it may be subjected to direct sunlight The electrical connections to the RT310 are made to the supplied industry standard backpl...

Page 6: ...acy of your thermostat from the default 0 5 C to 0 25 C This may cause your boiler to operate more frequently The DIP switches are located on the back of the thermostat ON 0 25 C OFF 0 5 C The span is...

Page 7: ...ry easy to operate These controls are shown below along with a description of each of their functions The temperature displayed on the LCD is the current room temperature All the LCD icons with a desc...

Page 8: ...Mode don t press any key for 10 seconds or press See the table below RESET Press the three buttons together for 3 seconds 3Sec 3Sec 3Sec dxx Function Parameter Description Default value d01 Temperatu...

Page 9: ...ion Mode Normal mode Room Temperature 22 0 C to be renewed within 5 seconds Setpoint Temperature 20 0 C C indicator On Frost Protection indicator Off Heat indicator Off Low Battery Warning indicator O...

Page 10: ...FROST button to activate Frost Protection The Setpoint temperature is automatically set to frost setpoint to prevent pipes from freezing If the room temperature is lower than the frost setpoint frost...

Page 11: ...econds to to do so without losing your settings Sleep Mode Press and hold and for 3 seconds simultaneously to enter the Sleep mode All the functions will be paused to save battery power While in sleep...

Page 12: ...ng 5 C Setpoint Temperature Range 5 C to 17 C Thermostat Power Source 2xAA Alkaline batteries Switch Rating Switching Voltage 0 230V Switching Current 3A resistance 1A inductance Protection Rating IP...

Page 13: ...cification for a period of two years from the date of installation SALUS Controls sole liability for breach of this warranty will be at its option to repair or replace the defective product Customer N...