background image

 

Use your created PIN to lock access to 

advanced settings menu.

23

14

19

Press TICK to allow installer or landlord 

to set service reminder and lock 

temperature level.

Using UP or DOWN, you can select YES 

and press TICK to confirm,or  you can 

select NO and go to point 20.

Using UP or DOWN, select the number of 

days service alert should last for.

Using UP or DOWN, select the warning 

period before the service alert will be 

activated, then press TICK.

Press TICK and enter installer’s phone 

number using UP and DOWN buttons.

Allows you to create a PIN which may 

be used to limit access to your settings. 

Using UP or DOWN,  create your PIN ac-

cess, then TICK to confirm.

20

21

22

Using UP or DOWN, enter the PIN code 

number. Press TICK to confirm every 

digit.

This option will allow you to lock your 

advanced settings using your access 

PIN. Using UP or DOWN,  create your lock 

advanced settings, then TICK to confirm.

Using UP or DOWN, select the lock 

temperature and then press TICK.

MENU / 

GRAB

TOP 

AND

BOTTOM

TO OPEN

OpenTherm is a method of control used by modern heating systems. Instead of switching a boiler on and off at 
intervals, modulating control allows the amount of heat provided by the boiler to be controlled to match the 
varying demand from the thermostat. This means the customer has greater system efficiency, energy saving 
and room comfort from our heating controls.

This menu will only be visible if your boiler is OpenTherm compatible and you have connected to  

terminals A and B.

This screen display will be displayed 

when OT is connected. To change the 

settings for DHW    and/or CH - press 

MENU and go to ADVANCED SETTINGS.

1

9

Using TICK, then UP and DOWN you can 

select FROST value . (5 - 17 degrees C). 

Press TICK to confirm or DOWN to see the 

next option.

10

Using TICK, then UP and DOWN you can 

set the maximum and the minimum 

room temperature.

2

Using UP or DOWN, navigate to HW 

SETPOINT and press TICK.

3

Using UP or DOWN, adjust the 

temperature and then press TICK.

4

Press TICK to enter menu. Using UP or 

DOWN, set  the maximum opentherm 

central heating temperature.

5

Using UP or DOWN, set the value then press TICK for 3 

sec to confirm and exit to main screen.

2

3

4

5

6

1

SERVICE REQUEST ERROR

LOCKOUT RESET ERROR

LOW WATER PRESSURE ERROR

GAS FLAME FAULT ERROR

AIR PRESSURE FAULT ERROR

WATER OVER TEMPERATURE ERROR

12

This will start your boiler early to impro-

ve energy saving.

13

15

17

18

16

This will stop your boiler early to improve 

energy saving.

11

If you think that the temperature 

displayed on the thermostat is not 

accurate due to its location, you can 

calibrate it using this menu with values 

between -3.5 / +3.5 degree.

Temporary Manual Override

For overriding the schedule to bring the 
HEAT on, use the UP button to increase the 
temperature and press TICK to accept the 
change.

7

This option is only for electrical radiators. 

Press TICK to confirm or DOWN to see the 

next option.

This is a simple ON/OFF algortihm 

control based on the set point. Using UP 

or DOWN, you can select the SPAN value.  

Press TICK to confirm or DOWN to go to 

next option.

8

CH (Central Heating)

HW (Hot Water)

MIN TEMP:  

25 °C

MIN TEMP:  

40 °C

MAX TEMP:  

80 °C

MAX TEMP:  

80 °C

DEFAULT TEMP:  

75 °C

DEFAULT TEMP:  

60 °C

2

3

Enter MENU and scroll down 

until you find „TEST LINK” 

option. Press TICK button to 

continue.

Now your thermostat is 

sending a TEST message to the 

receiver with the expectation 

of receiving a response.  While 

testing, both red and green 

LED will be intermittently 

flashing.

Your thermostat will indicate 

that the connection has been 

tested successfully and will 

return to normal operation.

1

Please note that below values can be manually set only if the boiler allows it.

ON

AUTO

The pairing between the thermostat and the 

receiver is already done at the factory. However, 

should you need to re-pair the units then this can 

be done using the User Menu. The link may also 

be tested from the User Menu to show pairing link 

has been successful. Before pairing, the Receiver 

should be unplugged, then plugged back in. 

During the pairing process, the distance between 

the Thermostat and the Receiver should be 

at least 1m.

2

3

4

Turn the receiver OFF and ON 

twice to reset.  Ensure receiver 

switches are ON and AUTO.  

Red LED should be flashing.  

Enter thermostat MENU and 

scroll down until you will see 

“PAIR WITH RECEIVER” option. 

Select YES to proceed with 

Pairing.

Now your thermostat is 

looking for the receiver. A 10 

minute counter will appear on 

the screen. 

Upon connecting to the 

receiver, the thermostat will 

display the message “PAIRING 

SUCCESSFUL” and return to 

normal operation afterwards. 

The red LED will stop flashing 

when the pairing is successful.

1

This setting will be valid until 

the next scheduled program. 

OpenTherm: Configuration

OpenTherm related errors:

Temperature Values for Opentherm

If an Opentherm fault is detected on the boiler, the thermostat will display the above 
messages. These errors are not related to the thermostat.

Additional installation notes for WQ610:

WQ610RF: Testing Link

WQ610RF: Pairing with the Receiver

Summary of Contents for Quantum WQ610

Page 1: ...Installer s Quick Guide X WQ610 WQ610RF ...

Page 2: ...e with Volt free switch and also Opentherm 4 0 connections so you can choose the method of control to suit your boiler installation Please note that the Boilers need to have an OpenTherm Association licensetobefullycompatiblewithWQ610range shouldyouwishtoconnecttotheOpenTherm terminals A and B Please verify if this requirement is met with your Boiler Manufacturer SafetyInformation Use in accordanc...

Page 3: ... icon is animating when there is heating demand 5 RF Connection indicator 6 CurrentTemperature Setpoint Temperature 7 Holiday mode indicator 8 Temporary override mode 9 Settings icon 10 Battery indicator 11 Schedule program number 12 Schedule mode icon 13 Day indicator SET information DO NOT connect to OpenTherm terminals unless your boiler is OpenTherm Association approved and has the OpenTherm L...

Page 4: ...e month and then press TICK which will then move todays thatcanbechangedinthesame way 1 TX thermostat Receiver TX thermostat Receiver TX thermostat VOLT FREE RT510TX Thermostat M R MAX 3 1 A Receiver COM L L N N NO AC 230 V MAX 16 5 A Please ensure the boiler has 230 V switching before wiring in this way Power Up and Configuration TheWQ610RF thermostat contains a re chargeable Lithium battery When...

Page 5: ...do so The Advanced Settings may be locked by the creation and activation of a 4 digit PIN code Please keep your PIN safe and secure 1 Press MENU 2 3 4 Press TICK to enter Daylight Saving Time Menu Using UP or DOWN select ON or OFF Press TICK to confirm UsingUPorDOWN navigatetoAdvanced submenu and press TICK 7 8 If you select NO thermostat will use dafult settings and revert to normal screen Once y...

Page 6: ...degrees C PressTICK to confirm or DOWN to see the next option 10 Using TICK then UP and DOWN you can set the maximum and the minimum room temperature 12 This will start your boiler early to impro ve energy saving 13 15 17 18 16 Thiswillstopyourboilerearlytoimprove energy saving 11 If you think that the temperature displayed on the thermostat is not accurate due to its location you can calibrate it...

Page 7: ...the varying demand from the thermostat This means the customer has greater system efficiency energy saving and room comfort from our heating controls This menu will only be visible if your boiler is OpenTherm compatible and you have connected to terminals A and B This screen display will be displayed when OT is connected To change the settings for DHW and or CH press MENU and go to ADVANCED SETTIN...

Page 8: ...e value then press TICK for 3 sec to confirm and exit to main screen 2 3 4 5 6 1 SERVICE REQUEST ERROR LOCKOUT RESET ERROR LOW WATER PRESSURE ERROR GAS FLAME FAULT ERROR AIR PRESSURE FAULT ERROR WATEROVERTEMPERATUREERROR OpenTherm related errors If an Opentherm fault is detected on the boiler the thermostat will display the above messages These errors are not related to the thermostat ...

Page 9: ...serMenutoshowpairinglink has been successful Before pairing the Receiver should be unplugged then plugged back in During the pairing process the distance between the Thermostat and the Receiver should be at least 1m 2 3 4 Turn the receiver OFF and ON twice to reset Ensure receiver switches are ON and AUTO Red LED should be flashing Enter thermostat MENU and scroll down until you will see PAIR WITH...

Page 10: ... techsupport salus tech com SALUS Controls is a member of the Computime Group Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification design and materials of products listed in this brochure without prior notice www salus tech com For PDF Installation guide please go to www salus manuals com ...