WQ610 / WQ610RF Thermostat

WQ610RF Receiver

1

2

3

4

5

6

7

8

1. 

MENU - enter the menu options, press and hold  

  for 3 seconds to return to main screen without  

 

saving changes.

2.  

DOWN - decrease the temperature and move  

 

through the menus.

3. 

UP - increase the temperature and move through  

 

the menus.

4. 

TICK - confirm changes and enter menus. 

 

 

  Press and hold for 3 seconds to exit User Menu  

  and save changes. Press and hold to cancel  

  BOOST feature or temporary override (whilst in  

 

normal screen).

5. 

ON - When in Manual Mode, ON will    

 

turn the boiler on.

6. 

OFF - When in Manual Mode, OFF  

 

 

will turn the boiler off.

7. 

AUTO - Receiver operates in automatic    

 

mode  according to the thermostat.

8. 

MANUAL - Receiver output is  

 

 

controlled by the On/Off slide switch.

Issue Date: Nov 2019

V006

WQ610

Thermostat

WQ610RF

Thermostat

Thermostat supply

230VAC

Lithium Battery  (Rechargable)

Thermostat rating max

3 (1) A

-

OpenTherm terminals

A / B

-

Outputs

Voltage free 
 NO / COM terminals

-

Temperature range

5°C – 35°C

5°C – 35°C

Thermostat display accuracy

 0.5°C

 0.5°C

ErP control class

Class V

Class V

Radio Frequency 

--

2.4 GHz

Dimension [mm]

86 x 86 x 27 [mm]

86 x 86 x 11[mm]

WQ610 Receiver

Receiver supply

230 V AC

Receiver rating max

16 (5) A

OpenTherm terminals

A / B

Outputs

Voltage free NO / COM terminals

Radio frequency

2.4 GHz

Dimension [mm]

98 x 98 x 32[mm]

SALUS Controls plc
SALUS House
Dodworth Business Park South,
Whinby Road, Dodworth,
Barnsley S75 3SP, UK

E: [email protected]
E: [email protected]

SALUS Controls is a member of the Computime Group.

Maintaining a policy of continuous product development SALUS Controls plc reserve 

the right to change specification, design and materials of products listed in this brochure 

without prior notice.

www.salus-tech.com

For PDF Installation guide please go to www.salus-manuals.com

WQ610RF Wiring Diagram

  1.  Menu/Settings description

  2.  Clock 24hr/AM/PM

  3.  Temperature unit

  4.  Heating indicator (icon is animating  

 

when there is heating demand)

  5.  RF Connection indicator

  6.  Current Temperature / Setpoint   

 Temperature

  7.  Holiday mode indicator

  8.  Temporary override mode

  9.  Settings icon

10.  Battery indicator

11.  Schedule program number

12.  Schedule mode icon

13.  Day indicator/ SET information

DO NOT connect to OpenTherm terminals unless your boiler is OpenTherm Association approved and 

has the OpenTherm Logo. 

3

2

To activate thermostat, press TICK button 

for 3 seconds (RF version) only.

Language ”ENGLISH” is flashing, press  

UP or DOWN, choose your language, then 

TICK to confirm.

4

Using UP or DOWN, choose the time 

format between 24 hr and 12 hr format.

Using UP or DOWN, set the hour and 

then press TICK, which will then move 

to minutes, that can be changed in the 

same way.

5

6

Using UP or DOWN, set the year and then 

press TICK.

Using UP or DOWN, set the month and 

then press TICK, which will then move 

to days, that can be changed in the same 

way.

1

2

13

12
11

1

3
4

5

6

7

9

10

8

TX thermostat

Receiver

TX thermostat

Receiver

Terminal

Description

B / A

OpenTherm Communication Wires only

NO

Volt free connection (Switch)

COM

Volt free connection (Common)

L; N

Supply (230 V AC)

Terminal

Description

A/B

OpenTherm Communication Wires only

NO

Volt free connection (Switch)

COM

Volt free connection (Common)

L;N

Supply (230 V AC) 

VOLT FREE

OPENTHERM

Installer’s Quick Guide

TX thermostat

5

ITLC helps to improve system efficiency 

and end user comfort. Default is ITLC 

Radiators

 (disabled if Opentherm 

connected)

. Press TICK to confirm or 

DOWN to see the next option.

6

Press TICK to select the type of heating 

control you prefer.

VOLT FREE

Advanced Settings allow the installer / landlord to adjust the thermostat to suit individual installation 

requirements. Do not adjust the settings unless you are competent to do so.  The Advanced Settings may be 

locked by the creation and activation of a 4 digit PIN code. Please keep your PIN safe and secure.

1

Press MENU.

2

3

4

Press TICK to enter Daylight Saving Time 

Menu.

Using UP or DOWN, select ON or OFF. 

Press TICK to confirm.

Using UP or DOWN, navigate to Advanced 

submenu and press TICK.

7

8

If you select NO, thermostat will use 

dafult settings and revert to normal 

screen.

Once you have properly connected your 

thermostat with the OpenTherm terminals 

the OT message will be shown on the 

screen. For more Opentherm details, go 

to the Opentherm: Configuration section.

L

R

T510T

X+

T

hermosta

t

R

T510T

X+

T

hermosta

t

N

M

CO

M

NO

NC

CO

M

NO

NC

OR

MAX

3 (1) A

AC 230 V

R

T510+

T

hermosta

t

R

T510+

T

hermosta

t

L

L

NO

N

N

COM

R

R

ec

eiv

er

R

ec

eiv

er

A

230 V

COM

L

L

N

N

NO

A

230 V

MAX

16 (5) A

Please ensure the boiler has 230 V switching before wiring in this way.

WQ610 / WQ610RF

Introduction

The SALUS Quantum WQ610 and WQ610RF thermostats  are Boiler Plus compatible thermostats, 
designed specifically to control central heating boilers and also in the case of the RF versions, 
electrical panel heaters. They have our new load compensation (ITLC) software with Volt free 
switch and also Opentherm 4.0 connections, so you can choose the method of control to suit 
your boiler / installation. Please note that the Boilers need to have an OpenTherm Association 
license to be fully compatible with WQ610 range(should you wish to connect to the OpenTherm 
terminals A and B). Please verify if this requirement is met with your Boiler Manufacturer.

Safety Information

Use in accordance with national and EU regulations. Use the device as intended, keeping it in 
a dry condition. Product is for indoor use only. Installation must be carried out by a qualified 
person in accordance with national and EU regulations.

Product Compliance

This product complies with the essential requirements and other relevant provisions of the following EU 
Directives: RED:2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of Conformity is available on: 
www.saluslegal.com            WQ610RF: 2405-2480MHz; <14dBm

WARNING! Always ensure the AC mains power is switched off before installing or working 

on any components.

Technical Specification

Button Functions

Power Up and Configuration

LCD Icon Description

WQ610 Thermostat Terminals Description

WQ610RX Receiver Terminals Description

WQ610 Wiring Diagram

Accessing Advanced Settings Menu

The WQ610RF thermostat contains a re-chargeable Lithium battery.  When the battery level 

is below 10%, the thermostat will display “PLEASE RE-CHARGE BATTERY”.  Please re-charge 

for a full 24 hours using a standard Micro USB charger.  Thermostat operation will not be 

affected during the charging period

OPENTHERM

230 V

Summary of Contents for Quantum WQ610

Page 1: ...Installer s Quick Guide X WQ610 WQ610RF ...

Page 2: ...e with Volt free switch and also Opentherm 4 0 connections so you can choose the method of control to suit your boiler installation Please note that the Boilers need to have an OpenTherm Association licensetobefullycompatiblewithWQ610range shouldyouwishtoconnecttotheOpenTherm terminals A and B Please verify if this requirement is met with your Boiler Manufacturer SafetyInformation Use in accordanc...

Page 3: ... icon is animating when there is heating demand 5 RF Connection indicator 6 CurrentTemperature Setpoint Temperature 7 Holiday mode indicator 8 Temporary override mode 9 Settings icon 10 Battery indicator 11 Schedule program number 12 Schedule mode icon 13 Day indicator SET information DO NOT connect to OpenTherm terminals unless your boiler is OpenTherm Association approved and has the OpenTherm L...

Page 4: ...e month and then press TICK which will then move todays thatcanbechangedinthesame way 1 TX thermostat Receiver TX thermostat Receiver TX thermostat VOLT FREE RT510TX Thermostat M R MAX 3 1 A Receiver COM L L N N NO AC 230 V MAX 16 5 A Please ensure the boiler has 230 V switching before wiring in this way Power Up and Configuration TheWQ610RF thermostat contains a re chargeable Lithium battery When...

Page 5: ...do so The Advanced Settings may be locked by the creation and activation of a 4 digit PIN code Please keep your PIN safe and secure 1 Press MENU 2 3 4 Press TICK to enter Daylight Saving Time Menu Using UP or DOWN select ON or OFF Press TICK to confirm UsingUPorDOWN navigatetoAdvanced submenu and press TICK 7 8 If you select NO thermostat will use dafult settings and revert to normal screen Once y...

Page 6: ...degrees C PressTICK to confirm or DOWN to see the next option 10 Using TICK then UP and DOWN you can set the maximum and the minimum room temperature 12 This will start your boiler early to impro ve energy saving 13 15 17 18 16 Thiswillstopyourboilerearlytoimprove energy saving 11 If you think that the temperature displayed on the thermostat is not accurate due to its location you can calibrate it...

Page 7: ...the varying demand from the thermostat This means the customer has greater system efficiency energy saving and room comfort from our heating controls This menu will only be visible if your boiler is OpenTherm compatible and you have connected to terminals A and B This screen display will be displayed when OT is connected To change the settings for DHW and or CH press MENU and go to ADVANCED SETTIN...

Page 8: ...e value then press TICK for 3 sec to confirm and exit to main screen 2 3 4 5 6 1 SERVICE REQUEST ERROR LOCKOUT RESET ERROR LOW WATER PRESSURE ERROR GAS FLAME FAULT ERROR AIR PRESSURE FAULT ERROR WATEROVERTEMPERATUREERROR OpenTherm related errors If an Opentherm fault is detected on the boiler the thermostat will display the above messages These errors are not related to the thermostat ...

Page 9: ...serMenutoshowpairinglink has been successful Before pairing the Receiver should be unplugged then plugged back in During the pairing process the distance between the Thermostat and the Receiver should be at least 1m 2 3 4 Turn the receiver OFF and ON twice to reset Ensure receiver switches are ON and AUTO Red LED should be flashing Enter thermostat MENU and scroll down until you will see PAIR WITH...

Page 10: ... techsupport salus tech com SALUS Controls is a member of the Computime Group Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification design and materials of products listed in this brochure without prior notice www salus tech com For PDF Installation guide please go to www salus manuals com ...

Reviews: