NSTRUCTIONS

'

Please read these instructions carefully 

before installing and using

 

the OPTIMA thermostat, and keep this guide in a safe place for future 
reference.  

 

Follow all local and electricity supplier regulations regarding the 
installation  or  replacement  of  a  thermostat.  An  authorized, 
qualified installer may be required.

 

 

Do  not  connect  any  of  the  terminals  to  the  110/220  VAC 
supply.

 The OPTIMA thermostat uses two AA batteries or a 24 

VAC power source.

 

 

Do not cover any of the vents on the thermostat. 

 

Do not install this unit at an altitude over 2000 meters.

 

 

Do  not  place  the  unit  in  a  bathroom  or  area  of  excessive 
moisture. Do not allow the unit to get wet. This device serves as 
a temperature control system only in dry, closed living and office 
spaces.

 

 

Do  not  expose  the  unit  to  temperatures  below  5

°

C  or  above 

40

°

C, humidity above 80%, or pollution above 

 

level 2. 

 

OPTIMA'ZigBee'Thermostat'

33

'

'

FCC'and'Industry'Canada'

RF Radiation Exposure statement

:  This equipment complies with FCC and 

Industry  Canada  RF  radiation  exposure  limits  set  forth  for  an  uncontrolled 

environment.  This  equipment  should  be  installed  and  operated  with  a 

minimum distance of 20 centimeters between the antenna and all persons.

 

Industry'Canada'

Under Industry Canada regulations, this radio transmitter may only operate 

using  an  antenna  of  type  and  maximum  (or  lesser)  gain  approved  for  the 

transmitter  by  Industry  Canada.  To  reduce  potential  radio  interference  to 

other  users,  the  antenna  type  and  its  gain  should  be  so  chosen  that  the 

equivalent  isotropically  radiated  power  (e.i.r.p.)  is  not  more  than  that 

necessary for successful communication.  
This  device  complies  with  Industry  Canada  licence-exempt  RSS  standard(s). 

Operation is subject to the following two conditions: (1) this device may not 

cause  interference,  and  (2)  this  device  must  accept  any  interference, 

including interference that may cause undesired operation of the device. 
Le  présent  appareil  est  conforme  aux  CNR  d'Industrie  Canada  applicables 

aux appareils radio exempts de licence. L'exploitation est autorisée aux deux 

conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) 

l'utilisateur  de  l'appareil  doit  accepter  tout  brouillage  radioélectrique  subi, 

même si le brouillage est susceptible d'en compromettre le fonctionnement. 

Summary of Contents for OPTIMA ZigBee

Page 1: ...Version 1 0 Salus Controls Inc 123 Townsend St Level LL2 San Francisco CA 94107 For other language versions please visit www salusinc com OPTIMA ZigBee Thermostat User Manual...

Page 2: ...limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20 centimeters between the antenna and all persons Industry Canada Under Ind...

Page 3: ...requency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur...

Page 4: ...POWER TO HVAC SYSTEM 7 DETERMINE WIRING CONFIGURATION 7 REMOVE OLD THERMOSTAT 9 INSTALL MOUNTING PLATE 9 ATTACH WIRING 10 INSTALL BATTERIES 10 INITIAL CONFIGURATION 11 ATTACH THERMOSTAT TO MOUNTING P...

Page 5: ...POINT TEMPERATURE 14 CHANGING THE OPERATING MODE 15 TURNING ON THE FAN 15 CONFIGURING THE THERMOSTAT 16 CONFIGURATION MENUS 16 RESET TO DEFAULTS 21 SPECIFICATIONS 22 TROUBLESHOOTING 23 SALUS WARRANTY...

Page 6: ...SYSTEM 29 SINGLE TRANSFORMER HEAT PUMP SYSTEM 30 TWO TRANSFORMER HEAT PUMP SYSTEM 31 APPENDIX B REGULATORY STATEMENTS 32 FCC STATEMENTS 32 FCC AND INDUSTRY CANADA 33 INDUSTRY CANADA 33 OPTIMA ZigBee...

Page 7: ...Conventional Two Transformer Heat and Cool System OPTIMA ZigBee Thermostat 1 IN THE BOX Thermostat with Mounting Plate Trim plate Screws and Anchors Wire Labels 2 x AA alkaline batteries User s Manua...

Page 8: ...Salus User Manual CONTROLS AND DISPLAY Buttons Slider Ring Next Previous Fan Hold Back Mode Enter Reset on bottom of unit OPTIMA ZigBee Thermostat 27 Conventional Single Transformer Heat and Cool Syst...

Page 9: ...increment or counter clockwise to decrement values Display next previous option Previous Tap to decrement values Display previous option Next Tap to Increment values Display next option FAN HOLD Back...

Page 10: ...ement as provided herein If a Product under warranty is defective the Customer may contact the party Seller from which the Customer purchased the Product to obtain an equivalent replacement product af...

Page 11: ...the Product Any implied warranties including warranties of merchantability or tness for a particular purpose are limited to the Warranty Period or the shortest period allowed by law SALUS SHALL NOT BE...

Page 12: ...eck that the connector pins are straight Check that the thermostat is fully seated on the mounting plate If the terminal connections are not fully engaged the firmware does not activate the relays Thi...

Page 13: ...Thermostat 7 Tools You may need the following tools to install the Optima thermostat Smartphone or camera to take pictures Phillips or flathead screwdriver Small screwdriver to disconnect wires from...

Page 14: ...P NonHHP Wire Color R RC RH C C L Y1 Y1 Y2 Y2 W1 W1 O B W2 G G OPTIMA ZigBee Thermostat 21 Reset To Defaults The RESET button is located on the bottom surface of the OPTIMA and can only be accessed wi...

Page 15: ...n the connected home system and updates the firmware automatically if one is found OPTIMA ZigBee Thermostat 9 Remove Old Thermostat Remove the old thermostat from the wall taking care not to allow the...

Page 16: ...ee Thermostat 19 Offset should the temperature sensor need calibration This value is added to the sensed temperature to determine the room temperature Range 7 F in 1 degree increments 4 C in 0 5 degre...

Page 17: ...nfiguration After inserting the batteries the display will flash all the segments followed by the firmware version number then display US CA with a blinking US When configuring the thermostat select t...

Page 18: ...ostat The thermostat can now be used as a local manual thermostat but to enable the enhanced features additional settings need to be configured See the Configuring the Thermostat section for more deta...

Page 19: ...to select another menu item at the same level To return to a higher level menu item at any time press the FAN HOLD button OPTIMA ZigBee Thermostat 13 USING THE THERMOSTAT The OPTIMA thermostat offers...

Page 20: ...ired set point temperature and press the FAN HOLD button while the set point temperature is blinking The word HOLD will appear in the Label Area to indicate the HOLD state OPTIMA ZigBee Thermostat 15...