10
'
Salus
User'
Manual
'
Attach'Wiring'
Before attaching the wires, match the wire (using
the labels) to its corresponding terminal. Refer to
the picture of the wiring taken earlier if
necessary.
•
Open the terminal by lifting the latch up.
•
Push each wire into the hole of the terminal
and push the latch down to secure the wire.
Install'Batteries'
Insert the alkaline batteries into the back of the
thermostat.
Make sure the polarities of the
batteries are correct.
Alkaline batteries are recommended as the Low
Battery sensor is tuned to alkaline batteries.
Warning
: Do not mix old and new batteries. Do
not mix different chemistries (Alkaline, Ni-Cad,
Lithium, etc.)
OPTIMA'ZigBee'Thermostat'
19
'
'
Offset – should the temperature sensor need calibration
This value is added to the sensed temperature to determine the
room temperature.
Range:
±7ºF in 1 degree increments
±4ºC in 0.5 degree increments
Default: 0 degrees
Span – temperature variance before taking action
This value determines the amount of temperature variation
allowed before calling for heat or cooling. Example: a span of 1ºF
with a set point of 70ºF will allow the room temperature to swing
between 69ºF and 71ºF without taking action.
Range:
0.5 – 2.0ºF in 0.5 degree increments
0.25 – 1.0ºC in 0.25 degree increments
Default: 0.5ºF (US), 0.25ºC (CA)
PAIR
This menu item allows the Optima ZigBee thermostat to be
connected to a compatible connected home system.
Pairing the OPTIMA to a connected home system is a coordinated
effort between the two systems. Following are general steps for the