Tel: 886.2.2175 2930 Email: [email protected]
46
40 frames, 50 frames,
Wave Intensity
0-15 16 ranks adjustable, with a progress bar to display.
5.6
Fast Action Buttons
AUTOSET: Automatically set the oscilloscope controls to generate a usable display of the input signals. Refer to
the following table for relative content.
SINGLE SEQ: Acquire a single waveform and then stop the acquisition.
RUN/STOP: Continuously acquire waveforms or stop the acquisition.
5.6.1
AUTOSET
Autoset is one of the advantages digital oscilloscopes have. When you push the AUTOSET button, the oscilloscope
will identify the type of waveform (sine or square wave) and adjust controls according to input signals so that it can
accurately display the waveform of the input signal.
Functions
Settings
Acquire Mode
Adjusted to Normal or Peak Detect
Cursor
Off
Display Format
Set to YT
Display Type
Set to Vectors for an FFT spectrum; otherwise, unchanged
Horizontal Position
Adjusted
SEC/DIV
Adjusted
Trigger Coupling
Adjusted to DC, Noise Reject or HF Reject
Trigger Holdoff
Minimum
Trigger Level
Set to 50%
Trigger Mode
Auto
Trigger Source
Adjusted; Autoset can not be used for the EXT TRIG signal