![Saluki Technology MSO1000 User Manual Download Page 45](http://html1.mh-extra.com/html/saluki-technology/mso1000/mso1000_user-manual_3616184045.webp)
Tel: 886.2.2175 2930 Email: [email protected]
www.salukitec.com
45
Push the DISPLAY button and the following menu appears.
Options
Settings
Comments
Type
Vectors
Dots
Vectors fills up the space between adjacent sample points in the display; Dots only
displays the sample points.
Persist
OFF
0.2S-8S selectable
Infinite
Sets the time length to display each displayed sample point.
Format
YT
XY
YT format shows the vertical voltage in relation to time (horizontal scale); XY format
displays a dot between CH1 and CH2 each time when a sample is acquired, where
the voltage or current of CH1 determines the X coordinate of the dot (horizontal) and
the voltage or current of CH2 determines the Y coordinate (vertical). For detailed
information, refer to descriptions on XY format in the following text.
Contrast
0-15 16 ranks adjustable, with a progress bar to display; Press F5 to select this
option. Turn the multi-functional knob to adjust.
Next Page
Grid
Dotted line
Real line
OFF
Off only displays the horizontal and vertical coordinates at the center graticule on the
screen.
Grid Intensity
0-15 16 ranks adjustable, with a progress bar to display.
5.6
Fast Action Buttons
AUTOSET: Automatically set the oscilloscope controls to generate a usable display of the input signals. Refer to
the following table for relative content.
SINGLE SEQ: Acquire a single waveform and then stop the acquisition.
RUN/STOP: Continuously acquire waveforms or stop the acquisition.
HELP: Display the Help menu.
DEFAULT SETUP: Recall the factory setup. Refer to the following table for relative content.
Save to USB Disk: Save all displays on the screen to a USB device, just like the screen capturing function of a
computer.