4.7 Seed Code

Thee Seed Code is an 8 digit random number needed to generate online Timed PIN Codes. 
If manually inserted, you have to keep track of the code and use it to generate valid Timed 
PIN Codes online. 

Only Low security codes can be generated with a custom user Seed Code. To generate HIGH 
Security codes and simplify the Timed Code generation, please use the WebApp to configure 
the device. 

Example: 

A confirmation beep will sound and the green LED will flash. 
The Seed Code has now been changed.

3

#

2

4

1

2

3

1

4

#

6

A confirmation beep will sound and the green and yellow 
LED’s will light. The keypad is now ready to receive a new 
Seed Code to generate timed PIN codes. Insert an 8 digit 
code.

Enter:

Summary of Contents for XS4 Mini

Page 1: ...e period It is easy to install and can be programmed via your mobile phone The battery pack electronic components and the locking mechanism are all located on the inside off the door to prevent vandal...

Page 2: ...tion 4 1 Service configuration menu 4 2 Factory reset 4 3 Clear all users 4 4 Change user configuration code 4 5 Change service configuration code 4 6 Special functions 4 7 Time and date configuration...

Page 3: ...ment section on page 6 to manage the fixed PIN s 2 ACCESS The keypad can grant access to open the locker in 3 different ways 1 INSTALLATION For instructions on the installation please check the instal...

Page 4: ...a new user Free Locker Mode must be enabled to use this function check Configuration on page 11 section of this manual Timed PIN codes are disabled when Free Locker Mode is enabled 1 0 0 1 Upon inser...

Page 5: ...h the time date and seed code to activate the timed PIN codes function Please see the Time and Date configuration and Seed Code sections on page 12 of this manual All required configurations are autom...

Page 6: ...plication or another registering tool To add or delete user codes it is necessary to access the User Configuration Menu Position User PIN 1 Carlos 148954 67 Torbj rn 94830132 179 Juan 1111 Exampel of...

Page 7: ...he green LED will blink until the fixed user PIN code is entered The fixed user PIN must be a number between 4 to 8 digits 9 7 1 To add users first insert a position to place the new PIN code between...

Page 8: ...confirmation beep will sound and all LED s will blink one time All the stored PIN codes are now deleted Enter 5 2 0 0 A confirmation beep will sound and all LED s will blink one time The keypad is aut...

Page 9: ...tion Code is inserted again to confirm the action Insert the code again 9 8 0 7 3 2 4 1 A confirmation beep will sound and the green LED will turn ON The keypad is ready to receive a new Service Confi...

Page 10: ...toggle the Special Function s state 1 2 3 ON OFF High Security encryption to all auto generated timed PIN codes With high security encryption all timed PIN s will have 8 digits Without high security...

Page 11: ...rt the hours e g 17 7 1 3 Insert the day e g 15th 5 1 2 Insert the month e g November 1 1 1 Insert the year e g 2022 2 2 A confirmation beep will sound yellow and red LED s will turn ON The keypad is...

Page 12: ...des can be generated with a custom user Seed Code To generate HIGH Security codes and simplify the Timed Code generation please use the WebApp to configure the device Example A confirmation beep will...

Page 13: ...s WebApp you can add devices users and configurations to your XS4 Code Locker Find our WebApp at https codelocker app 7 A confirmation beep will sound and all the LED s will light Enter After the seco...

Page 14: ...y change is performed 5 BATTERY MONITORING The device keeps the battery power level monitored all the time Two levels or warnings are per formed Three long beeps will sound after entering a valid code...

Page 15: ...he battery holder and hold it 3 Insert the batteries again Wait until a confirmation beep sounds and all LED s blink once 4 Release the button The keypad will restart A startup beep sounds and all the...

Page 16: ...t projection 15 mm Power source 3 alkaline batteries LR03 AAA 1 5V Optional 3 Lithium batteries FR03 AAA 1 5V Number of openings Up to 2 years depending on usage Environmental conditions Temperature 2...

Reviews: