1. GENERAL

1.1 Applications

For the pumping of all clear liquids that are chemically neutral and
contain no abrasive particles in suspension.

• Central heating
• Air conditioning
• Cold water circuit
• Water transfer

1.2 Specifications
LRLA

Set consisting of pump im coupling shaft + lantern
assembly.

JRLA

Set consisting of dual 2 imp 2 coupling 2 lan-
tern assemblies and a discharge check valve allowing single- and
dual-pump operation.

The suction and discharge ports are in-line.

• Max. service pressure

: 10 bar 

• Temperature range 

: - 10 °C à + 110 °C

ISO PN 10 flanges (NF E 29203) with gasket contact face.

2. SAFETY

LRead these instructions carefully before installing and starting up.
Pay special attention to the points concerning the safety of the
equipment for the intermediate or end user.

2.1 Symbols used in the manual

Warning.

Instruction concerning electricity.

Calls attention to a potential risk that might affect
the safety of people.

3. TRANSPORT AND STORAGE

When taking delivery of the equipment, check that it has not been
damaged in transport.  If anything is found wrong, take the necessa-
ry steps with the carrier within the allowed time.

If the equipment delivered is to be installed at a later time, store it in
a dry place and protect it from impacts and outside influences (mois-
ture, frost, etc.)

.

For a normal shutdown:

- Close the discharge valve and stop the pump.

For a prolonged shutdown, if there is a risk of frost:

- Close both pump isolating valves and if necessary drain the pump

casing (through the plug(s) provided on some pumps).

- When starting back up, check that the motors turn freely, without 

sticking; fill the pump and the suction pipe; bleed the mechanical 
seal.

4. PRODUCTS AND ACCESSORIES

4.1 Description
single and dual pumps (see Fig. 1)

1111A : Single pump casing (LRLA)
1111B : Dual pump casing (JRLA)

2250

: Impeller

3132

: Lantern

4220

: Rotating part

4240

: Fixed part

4610A : Pump casing O-ring

6545A : Keeper ring on shaft
6545B : Keeper ring on shaft

7114

: Coupling shaft 

7450

: Coupling guard

8010

: Electric motor with standard flange

9621A : Pressure tap plug
9621B : Pump casing drain plug (LRLA)
9638

: Mechanical seal air bleed

9647

: Check-valve assembly (JRLA)

9902A : Lantern casing/bearing attachment screw
9910

: Coupling/motor shaft attachment screw

9906

: Motor attachment screw

9923

: Motor attachment nut

9940

: Mechanical seal thrust ring

9941

: Washer for motor attachment

(recommended spares in bold type): 

These are recommendations only, since the frequency of replace-
ment will depend on the conditions of use of the unit: 

- for the mechanical seal, the quality, temperature, and pressure of 

the pumped liquid;

- for the motor and the other components, the load and the 

ambient temperature.

4.2 Motor
For use of a motor, not supplied, with standard IM B5 or IM V1 flange
(CEI standards) or C-Face flange (NEMA standards).

Speed of rotation in rpm, 50-Hz version

: 2900 or 1450

Speed of rotation in rpm, 60-Hz version

: 3500 or 1750

Winding

: depends on motor

Frequency

: 50 Hz & 60 Hz

Insulation class

: depends on motor

Protection index

: depends on motor

4.3 Possible accessories and options

- 439 DS motor protection circuit-breakers (LRLA)
- Y1200 motor protection and control box (JRLA)
- PN 10 round weld-on counter-flange
- Anti-vibration sleeve
- Isolating valve
- Pressure kit
- Blanking cover
- Baseplate for ND 65 and 80.

Sealing: 

By maintenance-free self-lubricating mechanical seal with friction
faces:
- carbon/silicon carbide/EP seal

5. INSTALLATION

Install the pump in an easy-to-reach location.
If the motor is heavy (lifting tackle required), provide a point of
attachment (rail or lifting hook) in the centreline to make it easy to lift
the motor clear.  
The pump may be connected directly to the piping or (better) instal-
led on a foundation block with proper sound and vibration damping.

5.1 Direct mounting on pipe (see Fig. 1)

May be installed in any position except blower cover down.

5.2 Installation on foundation block

The size of the block should be appropriate to the weight and dimen-
sions of the pump.
If the installation includes several pumps, they may be installed on the
same foundation provided that proper sound and vibration damping
practice is followed.

ATTENTION !

MECHANICAL SEAL

ENGLISH

Summary of Contents for LRLA

Page 1: ...NGLE AND DUAL HEAD IN LINE PUMPS WITH COUPLINGS FRANCAIS ENGLISH INSTALLAZIONE E MESSA IN SERVIZIO DELLE ELETTROPOMPE IN LINEA UN SOLO CORPO E A DOPPIO CORPO ITALIANO INSTALACION Y PUESTA EN SERVICIO...

Page 2: ...OMPATIBILIDADE ELECTROMAGN TICA POMPES SALMSON declara que os materiais designados no presente cat logo obedecem s disposi es da directiva M QUINAS modificada Directiva 89 392 CEE e COMPATIBILIDADE EL...

Page 3: ...50 U V W Z X Y MOT 1 MOT 2 2 4 6 U V W Z X Y 2 4 6 1 2 3 4 N L1 L2 L3 3 Ph 230V ou 3 Ph 400V N L1 L2 L3 or L1 L2 L3 U V W Z X Y D1 D2 2 4 6 98 97 96 95 2 4 6 14 1 3 5 13 Y1200 JRLA 439 DS LRLA U V W Z...

Page 4: ...bre accouplement 7450 Protecteur d accouplement 8010 Moteur lectrique bride standard 9621A Bouchon prise manom tre 9621B Bouchon de vidange corps de pompe LRLA 9638 Purgeur d air garniture m canique 9...

Page 5: ...l aide d un tournevis D visser en partie les vis 9910 de l accouplement 7114 Placer le moteur sur la lanterne 3132 en prenant soin de positionner la rainure de clavette de l arbre moteur face au vis...

Page 6: ...toute la tuyauterie c Contr ler l tanch it de toute la conduite jusqu la pompe et tancher d R amor er par remplissage pompe V rifier l tanch it du clapet de pied e Trop de pertes de charge l aspirati...

Page 7: ...ft 7450 Coupling guard 8010 Electric motor with standard flange 9621A Pressure tap plug 9621B Pump casing drain plug LRLA 9638 Mechanical seal air bleed 9647 Check valve assembly JRLA 9902A Lantern ca...

Page 8: ...arate the two coupling guards 7450 using a screwdriver Partially unscrew the screws 9910 of the coupling 7114 Place the motor on the lantern 3132 taking care to align the motor shaft key slot with the...

Page 9: ...b Clean the whole pipe c Check the tightness of the whole pipe up to the pump and seal it d Fill the pump to reprime Check the tightness of the foot valve e Excessive loss of suction head or suction...

Page 10: ...resto su albero 6545B Anello di arresto su albero 7114 Albero di accoppiamento 7450 Protettore di accoppiamento 8010 Motore elettrico a flangia standard 9621A Tappo di presa manometro 9621B Tappo di s...

Page 11: ...el motore Smontare i due protettori di accoppiamento 7450 con un cacciavite Allentare le viti 9910 dell accoppiamento 7114 Posare il motore sulla lanterna 3132 posizionando la scanalatura di chiavetta...

Page 12: ...sino alla pompa e ristabilirne la tenuta stagna d Riadescare riempiendo la pompa Verificare la tenuta stagna della valvola di fondo e Perdite eccessive di carico all aspirazione o altezza di aspirazio...

Page 13: ...5A Anillo de seguridad 6545B Anillo de seguridad 7114 Arbol de acoplamiento 7450 Protector de acoplamiento 8010 Motor el ctrico de brida est ndar 9621A Conexion para man metro 9621B Tap n de vaciado c...

Page 14: ...r ambos protectores de acoplamiento 7450 Destornillar parcialmente los tornillos 9910 del acoplamiento 7114 Colocar el motor sobre la linterna motor 3132 procurando situar la ranura de chaveta del rbo...

Page 15: ...nqueidad de todo el conducto hasta la bomba y hacerlo estan co d Recebar llenando la bomba Ver la estanqueidad de la v lvula de pie e Demasiadas p rdidas de carga en la aspiraci n o la altura de aspir...

Page 16: ...E14 2WJ TEL 44 12 83 52 30 00 FAX 44 12 83 52 30 90 PORTUGAL Rua Alvarez Cabral 250 254 4050 040 Porto TEL 351 22 208 0350 FAX 351 22 200 1469 mail salmson pt P S SEA Pte Lte SINGAPORE 1 Claymore Driv...

Reviews: