61
EN
6. INSTALLATION.
6.1. MECHANICAL INSTALLATION.
In this section, the new devices are physically inserted into the
protection panel of the existing installation.
Materials required:
1
1.
Separate the IGA and ID protection elements, leaving
a minimum separation of 48 mm between them.
2.
Place the SLC ENERGY MANAGER device on the DIN rail of
the installation's protection box in the separation space that
has been enabled.
In the direction from the connection to the installation, first
place the SLC ENERGY MANAGER device.
3.
Ensure that the device has the DIN rail retaining tabs inserted
correctly in the lower part.
ICP
IGA
ID
PIAs
SLC ENERGY
MANAGER
Fig. 4. DIN rail installation, single-phase model.
ICP
IGA
ID
PIAs
SLC ENERGY
MANAGER
Fig. 5. DIN rail installation, three-phase model.
SLC ENERGY MANAGER
ENERGY METER
USER MANUAL
Summary of Contents for Equinox SLC EM Lite
Page 1: ...SLC EM Lite SLC EM SLC EM T ES EN FR MANUAL DE USUARIO ENERGY MANAGER...
Page 38: ...38 SALICRU...
Page 39: ...39 ES SLC ENERGY MANAGER ENERGY METER USER S MANUAL...
Page 40: ...40 SALICRU Tambi n es posible acceder a la informaci n de los inversores instalados...
Page 49: ...49 ES SLC ENERGY MANAGER ENERGY METER USER S MANUAL...
Page 51: ...SLC EM Lite SLC EM SLC EM T EN USER MANUAL ENERGY MANAGER...
Page 88: ...88 SALICRU...
Page 89: ...89 EN SLC ENERGY MANAGER ENERGY METER USER MANUAL...
Page 90: ...90 SALICRU It is also possible to access information on installed inverters...
Page 99: ...99 EN SLC ENERGY MANAGER ENERGY METER USER MANUAL...
Page 101: ...SLC EM Lite SLC EM SLC EM T FR MODE D EMPLOI ENERGY MANAGER...
Page 138: ...138 SALICRU...
Page 139: ...139 FR SLC ENERGY MANAGER ENERGY METER MANUEL D UTILISATEUR...
Page 149: ...149 FR SLC ENERGY MANAGER ENERGY METER MANUEL D UTILISATEUR...